Suspended PCA100 Heat Pump

Large Room System // PCA-M100KA

Our Suspended PCA100 high performance heat pump is designed for style and efficiency. With four speed settings and auto air-speed adjustment it is ideal for mid-sized areas. Upgraded with a Deluxe PAR31 wired Controller, with backlit LCD display and user friendly menus. With the PAR31 you are able to precisely control power consumption and temperature, setting up to eight patterns per day.

Cooling Capacity10.0 kW
Heating Capacity11.2 kW
Select a Size - R32 Refrigerant
Select a Size - R410A Refrigerant
Select a Contoller

Features

Stylish Design

Sharp, clean lines make this unit blend in more easily with your ceiling, providing low-profile heating or cooling.

Next Generation R32 Technology

R32 is a refrigerant with just one-third the global warming potential of R410A and has zero ozone depletion potential. R32 offers increased energy efficiency, and is said to be the next generation of refrigerants

Automatic Air Speed Adjustment

In addition to the conventional 4-speed setting, our suspended units are now equipped with an automatic air-speed adjustment mode. This setting automatically adjusts the air speed to match the room environment. At the start of heating or cooling operation, the airflow is set to high-speed to quickly heat or cool the room. When the room temperature reaches your desired setting, the airflow speed is decreased automatically for stable comfortable heating or cooling operation.

Fresh Air Intake Option

Units are equipped with an opening that enables the induction of fresh outside air.

Deluxe PAR Weekly Controller

This attractive full dot liquid crystal display incorporates a large backlit screen and simple menus for easy operation. You can set up to 8 temperature and airflow patterns per day for seven days, allowing you to reduce your energy consumption when needed, saving you both time and money. Perfect for the busy home and office or retail store.

Click here to find out more

High and Low Ceiling Modes

Units are equipped with high and low ceiling operation modes that make it possible to switch the airflow volume to match room height. The ability to choose the optimum airflow volume makes it possible to optimise the breezy sensation felt throughout the room.

Specifications

PCA-M100KA // Suspended PCA100 Heat Pump System

· Function: Cooling/Heating · Type: Single Split, Inverter
Rated
· Capacity - Cooling: 10.0 kW · Capacity - Heating: 11.2 kW
· Capacity - Cooling (min. - max.): 4.9 - 11.4 kW · Capacity - Heating (min. - max.): 4.5 - 14.0 kW
· Power input - Cooling: 2.55 kW · Power input - Heating: 3.28 kW
· Star rating - Cooling: NA · Star rating - Heating: NA
· EER / COP: 3.92 / 3.41 · AEER / ACOP: 3.77 / 3.31
· Current - Cooling [In+Outdoor] (Rated): 11.60 A · Current - Heating [In+Outdoor] (Rated): 14.30 A
· Current (Max.): 28.15 A
Performance
· Operation Range - Cooling: -5 / +52 degC · Operation Range - Heating: -20 / +21 degC

PCA-M100KA - Ceiling Suspended Indoor Unit

· Function: Cooling/Heating · Type: Single Split, Inverter
Nominal Capacity
· Capacity - Cooling: 10.0 kW · Capacity - Heating: 11.2 kW
· Sound Level - Cooling (Low - Super High, dB(A)): 37 / 39 / 41 / 43 · Sound Level - Heating (Low - Super High, dB(A)): 37 / 39 / 41 / 43
· Air volume - Cooling (Super High, Litre/sec): 467 · Air volume - Heating (Super High, Litre/sec): 467
· Refrigerant: R32 · Liquid pipe size (OD, mm): 9.52
· Gas pipe size (OD, mm): 15.88 · Max. pipe length (m): 75
· Max. pipe height (m): 30 · Power supply: 230V / Single Phase / 50 Hz
· Dimensions (WxDxH, mm): 1600 x 680 x 230 · Weight: 37.0 kg

PUZ-ZM100VKA-A - R32 Inverter Outdoor Unit

· Function: Cooling/Heating · Type: Single Split, Standard Inverter
· Operation Range - Cooling: -5 / +52 degC · Operation Range - Heating: -20 / +21 degC
· Sound Level - Cooling (dB(A)): 49 · Sound Level - Heating (dB(A)): 51
· Air volume - Cooling (Litre/sec): 1833 · Air volume - Heating (Litre/sec): 1833
· Power supply: Single phase, 230 V, 50Hz · Refrigerant: R32
· Liquid pipe size (OD, mm): 9.52 · Gas pipe size (OD, mm): 15.88
· Max. pipe length (m): 75 · Max. pipe height (m): 30
· Dimensions (WxDxH, mm): 1050 x 330 x 1338 · Weight: 113kg

·  Rating Conditions (AS / NZS 3823):
   Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB.     Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

·  Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

·  Dry function will not work when the room temperature is below 13°C.

·  Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

·  Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

·  Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
   EER = Energy Efficiency Ratio
   COP = Coefficient of Performance
   AEER# = Annual Energy Efficiency Ratio
   ACOP# = Annual Coefficient of Performance
   #These include standby power in the rating calculation

Downloads

Support

Optional

Connect multiple indoor units to a single outdoor unit.

This system gives you the freedom to select the indoor model best suited to each and every room in your home. Multi-Split Systems are designed to allow multiple indoor units of varying capacity and type to be connected to just one outdoor unit, enhancing exterior aesthetics by reducing the number of outdoor units required.

PCA-M100KA Indoor Unit can be connected to the following Multi Room Systems.

Multi-Split system outdoor unit. (WxDxH, mm): 1050 x 330(25) x 981. Cooling/Heating capacity: 12.5/14.0kW. Weight: 93kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 162. Central Branch Box(s): When installing two Branch Boxes, use Brazing or Flare Tee for dual Branch Box Connection.
Multi-Split system outdoor unit. (WxDxH, mm): 1050 x 330(25) x 981. Cooling/Heating capacity: 14.0/16.0kW. Weight: 93kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 182. Central Branch Box(s): When installing two Branch Boxes, use Brazing or Flare Tee for dual Branch Box Connection.
Multi-Split system outdoor unit. (WxDxH, mm): 1050 x 330 x 981. Cooling/Heating capacity: 15.5/16.5kW. Weight: 93kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 202. Central Branch Box(s): When installing two Branch Boxes, use Brazing or Flare Tee for dual Branch Box Connection.
Ceiling Suspended