Two Port 5.2kW Outdoor Heat Pump

Multi Room System // MXZ-2D52VA-A2

The two port multi room outdoor unit allows you to connect 2 indoor units, up to a Class 50, with a maximum total Class of 75. Choose the indoor unit best suited to each room’s style and size, and keep your home’s exterior looking neat with only one outdoor multi room unit.

Cooling Capacity5.2 kW
Heating Capacity6.1 kW
Select a Size

Features

Style for Each and Every Room

With our multi room systems, you have the flexibility to choose the perfect indoor unit for each room. You may want a super quiet, low capacity unit for a smaller bedroom and a stylish, higher capacity unit for the larger living room. With a multi room system, you are able to connect these to a single outdoor unit, rather than requiring one for each indoor – saving outdoor space and maintaining your home’s exterior aesthetics.

Energy Savings

Mitsubishi Electric Inverter control distributes tempered air in the shortest period of time and ensures that the system operates at ideal capacity, minimising energy wastage.

Personalised, Individual Control

Our multi room systems allow individual control of every heat pump in your home; whether you want to increase the temperature in the kid’s bedroom before bedtime, or turn off the living room heat pump as you head out for dinner. With individual heat pump control, you can adjust the temperature to suit your comfort levels and ensure a heat pump is only operating when needed.

Quiet Operation for Peaceful Comfort

Our multi room outdoor units are equipped with a Silent Mode; ensuring outdoor sound levels remain as low as possible during operation.

Come Home to Total Comfort with Wi-Fi Control

Whether you’re on your way home, running late, or even when you’re in a different country, Wi-Fi Control lets you control your multi room heat pump system to suit your lifestyle. With the purchase of a Wi- Fi interface for each indoor unit, your multi room system can be seamlessly controlled and monitored no matter where you are.

Specifications

· Function: Cooling/Heating · Type: Multi Split, Inverter
· Multi-Split System Compatible: Yes · Number of indoor units: 1 or 2
· Capacity - Cooling: 5.2 kW · Capacity - Heating: 6.1 kW
· Capacity - Cooling (min. - max.): 1.1 - 6.0 kW · Capacity - Heating (min. - max.): 1.0 - 7.0 kW
· Power input - Cooling: 1.40 kW · Power input - Heating: 1.59 kW
· EER / COP: 3.88 / 4.07 · AEER / ACOP: 3.83 / 4.04
· Operation Range - Cooling: -10 / +46 degC · Operation Range - Heating: -15 / +24 degC
· Sound Level - Cooling (dB(A)): 50 · Sound Level - Heating (dB(A)): 53
· Current - Cooling (Rated / Max.): 6.3 / 12.2 A · Current - Heating (Rated / Max.): 7.1 / 12.2 A
· Air volume - Cooling (Litre/sec): 525 · Air volume - Heating (Litre/sec): 532
· Refrigerant: R410A · Liquid pipe size (OD, mm): 6.35 x2
· Gas pipe size (OD, mm): 9.52 x2 · Max. pipe length (m): 30 total / 20 each
· Max. pipe height (m): 15* · Power supply: 230V / Single Phase / 50 Hz
· Dimensions (WxDxH, mm): 800 x 285 x 550 · Weight: 37 kg
· [*1]: If the outdoor is installed higher than the indoor max. height is reduced to 10m.

·  Rating Conditions (AS / NZS 3823):
   Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB.     Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

·  Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

·  Dry function will not work when the room temperature is below 13°C.

·  Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

·  Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

·  Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
   EER = Energy Efficiency Ratio
   COP = Coefficient of Performance
   AEER# = Annual Energy Efficiency Ratio
   ACOP# = Annual Coefficient of Performance
   #These include standby power in the rating calculation

Connectable Indoors

Connect multiple indoor units to a single outdoor unit.

This system gives you the freedom to select the indoor model best suited to each and every room in your home. Multi-Split Systems are designed to allow multiple indoor units of varying capacity and type to be connected to just one outdoor unit, enhancing exterior aesthetics by reducing the number of outdoor units required.

If more than one room requires heating and cooling, a Multi-Split system may be right for you. This system allows the indoor units chosen to reflect the specific needs of each room. For example, a whisper-quiet high wall could be selected for a bedroom, while a floor console could be used to replace a fireplace in the living room. The indoor units selected will be powered by just one outdoor unit, lowering the overall capital cost and increasing the energy efficiencies achieved.

Connectable Indoor Unit Types.

Every home is different, and with so many options to choose from it is important to consider each individual room’s requirements as part of the overall Multi Room system.

Use the following learn more about the different indoor unit types available, as well as controller options. This information can then be used to base your preferred selection of indoor units and control systems that best suit your home.

Multi Room Systems need to be specified by a Mitsubishi Electric Authorised Installer

Final selections should always be based on an in-home quote from a qualified Mitsubishi Electric Authorised Installer.


Downloads

Support

Classic Multi Series