Classic GE 50 High Wall

Medium Room System // MSZ-GE50VA

Our Classic GE50 is very, very quiet. The classic neutral design, energy saving features and mid-range capacity make it the perfect heat pump if you are looking to heat a moderately sized room and you live in a mild climate.

Cooling Capacity5.0 kW
Heating Capacity5.8 kW
$2,749.99
RRP and excludes install costs*
Select a Size







Quietness

Starting from barely a whisper, our Classic GE50 allows you to feel the warmth, not hear it. The GE range starts from a hushed 19dBA indoor sound and contains New Zealand’s quietest heat pumps ever.

Energy Efficiency

Combining efficient technology with unique energy saving features our GE Series systems will contribute to reduced energy consumption in your home or office. Our i-save and Econo Cool modes are included on all GE models. i-save mode allows you to save temperature and fan speed combinations, returning to these at the touch of a button and Econo Cool provides maximum energy energy efficiency in cooling mode.

MSZ-GE50VA-A1 - DC Inverter High Wall

· Function: Cooling/Heating · Type: Single Split, Inverter
· Capacity - Cooling: 5.0 kW · Capacity - Heating: 5.8 kW
· Capacity - Cooling (min. - max.): 1.4 - 5.4 kW · Capacity - Heating (min. - max.): 1.4 - 7.2 kW
· Power input - Cooling: 1.64 kW · Power input - Heating: 1.65 kW
· Power input - Cooling (min. - max.): 0.32 - 2.06 kW · Power input - Heating (min. - max.): 0.32 - 2.49 kW
· Star rating - Cooling: 1.5 · Star rating - Heating: 2.5
· EER / COP: 3.12 / 3.63 · AEER / ACOP: 3.05 / 3.55
· Previous Star rating: 4.5 / 5.0 · Sensible - Cooling: 3.61 kW
· Dry Mode (Moisture Removal, Litre/hr): 1.8
· H2 Capacity - Heating*: 4.93 kW · H2 Power input - Heating*: 1.46 kW
· H2 COP - Heating*: 3.37
· Operation Range - Cooling: -10 / +46 degC · Operation Range - Heating: -15 / +24 degC
· Sound Level - Cooling (Quiet - Super High, dB(A)): 28 / 33 / 38 / 44 / 49 · Sound Level - Heating (Quiet - Super High, dB(A)): 28 / 33 / 37 / 43 / 48
· Current - Cooling [in+outdoor] (Rated / Max.): 7.4 / 13.0 A · Current - Heating [in+outdoor] (Rated / Max.): 7.4 / 13.0 A
· Air volume - Cooling (Super High, Litre/sec): 251.7 · Air volume - Heating (Super High, Litre/sec): 241.7
· Refrigerant: R410A · Liquid pipe size (OD, mm): 6.35
· Gas pipe size (OD, mm): 12.7 · Max. pipe length (m): 30
· Max. pipe height (m): 15 · Power supply: 230V +/- 10% / Single Phase / 50 Hz
· Dimensions (WxDxH, mm): 798 x 232 x 295 · Weight: 10 kg
· *Note: H2 is tested data

MUZ-GE50VA - DC Inverter Outdoor Unit

· Function: Cooling/Heating · Type: Single Split, Standard Inverter
· Operation Range - Cooling: -10 / +46°C · Operation Range - Heating: -15 / +24°C
· Sound Level - Cooling (dB(A)): 54 · Sound Level - Heating (dB(A)): 56
· Air volume - Cooling (Litre/sec): 817 · Air volume - Heating (Litre/sec): 817
· Power supply: 240V +/- 10% / Single Phase / 50 Hz · Refrigerant: R410A
· Liquid pipe size (OD, mm): 6.35 · Gas pipe size (OD, mm): 12.7
· Max. pipe length (m): 30 · Max. pipe height (m): 15
· Dimensions (WxDxH, mm): 840 x 330 x 850 · Weight: 54 kg

·  Rating Conditions (AS / NZS 3823):
   Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB.     Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

·  Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

·  Dry function will not work when the room temperature is below 13°C.<

·  Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

·  Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

·  Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
   EER = Energy Efficiency Ratio
   COP = Coefficient of Performance
   AEER# = Annual Energy Efficiency Ratio
   ACOP# = Annual Coefficient of Performance
   #These include standby power in the rating calculation

PAR-21MAA
Our PAR21, wired LCD seven day controller allows you to program up to eight separate start/stop patterns per day over a week.
PAR-30
Our PAR31 wired seven day controller with backlit LCD screen allows you to program up to eight separate start/stop patterns per day over a week.
MAC-333IF-E
MA, M-NET and Contact Terminal Interface. Has remote on/off, prohibit/permit control and run/error outputs - all outputs require an independent external 12VDC power supply. Used to connect PAR-21 / PAR-31 to; MSZ-GE/FB/EF, MFZ-KA/FB & SLZ-KA~VAL indoor units or a Central / Schedule Controller to each indoor unit connected to a M or S-Series outdoor unit.

Connect multiple indoor units to a single outdoor unit.

This system gives you the freedom to select the indoor model best suited to each and every room in your home. Multi-Split Systems are designed to allow multiple indoor units of varying capacity and type to be connected to just one outdoor unit, enhancing exterior aesthetics by reducing the number of outdoor units required.

MSZ-GE50VA Indoor Unit can be connected to the following Multi Room Systems.

MXZ-3C54VA
Multi-Split system outdoor unit. (WxDxH, mm): 840 x 330 x 710. Cooling/Heating capacity: 5.4/7.0kW. Weight: 57kg. Liquid / Gas Pipe (OD, mm): 6.35 x3 / 9.52 x3. Requires a minimum combination of 1 and a maximum of 3 indoor units (up to Class 50), with max. class total of 100.
MXZ-4C71VA
Multi-Split system outdoor unit. (WxDxH, mm): 840 x 330 x 710. Cooling/Heating capacity: 7.1/8.6kW. Weight: 58kg. Liquid / Gas Pipe (OD, mm): 6.35 x4 / 9.52 x3 + 12.7 x1. Requires a minimum combination of 1 and a maximum of 4 indoor units (up to Class 60), with max. class total of 125.
MXZ-4B80VA-A1
Multi-Split system outdoor unit. (WxDxH, mm): 900 x 320 x 900. Cooling/Heating capacity: 8.0/9.4kW. Weight: 67kg. Liquid / Gas Pipe (OD, mm): 6.35 x4 / 9.52 x3 + 12.7 x1. Requires a minimum combination of 1 and a maximum of 4 indoor units (up to Class 71), with max. class total of 145. Note: The MXZ-4C80VA can only use 1x class 71 indoor.
MXZ-5C100VA
Multi-Split system outdoor unit. (WxDxH, mm): 900 x 320 x 900. Cooling/Heating capacity: 10.0/12.0kW. Weight: 68kg. Liquid / Gas Pipe (OD, mm): 6.35 x5 / 9.52 x4 + 12.7 x1. Requires a minimum combination of 1 and a maximum of 5 indoor units (up to Class 71), with max. class total of 171.
MXZ-6C120VA-A1
Multi-Split system outdoor unit. (WxDxH, mm): 900 x 320 x 1070. Cooling/Heating capacity: 12.0/14.0kW. Weight: 68kg. Liquid / Gas Pipe (OD, mm): 6.35 x6 / 9.52 x5 + 12.7 x1. Requires a minimum combination of 1 and a maximum of 6 indoor units (up to Class 80), with max. class total of 180.
MXZ-8B140VA
Multi-Split system outdoor unit. (WxDxH, mm): 950 x 330 x 1350. Cooling/Heating capacity: 14.0/16.0kW. Weight: 129kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 71), with max. class total of 185. Central Branch Box(s): Two Branch boxes required if installing more than 5 indoors with Brazing Tee for dual Branch Box Connection.
MXZ-8B160VA
Multi-Split system outdoor unit. (WxDxH, mm): 950 x 330 x 1350. Cooling/Heating capacity: 15.5/18.0kW. Weight: 139kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 202. Central Branch Box(s): Two Branch boxes required if installing more than 5 indoors with Brazing Tee for dual Branch Box Connection. To connect to a 10.0kW indoor unit a Y-Connector is needed.
*Actual price may differ. Excludes install costs.