Classic KA50 Floor Console

Medium Room System // MFZ-KA50VA

Our Classic KA50 heat pump with its slim design sits discreetly at floor level. With upper and lower vanes, our floor consoles will provide you with optimum air distribution.

Cooling Capacity4.8 kW
Heating Capacity6.0 kW
$3,899.99
RRP and excludes install costs*
Select a Size



Quick, Effective Heating or Cooling

Our compact floor console series ensures perfect room temperatures are achieved with both upper and lower vanes distributing air and eliminating draughts while heating.

Mitsubishi Electric Inverter control distributes tempered air in the shortest period of time and auto-changeover mode allows the heat pump to switch between modes ensuring that the room is kept at your chosen temperature. Perfect for those cold winter months!

Superior Design

Compact and slimline, our floor console range has been designed as an unobtrusive addition to any area. An ideal solution for replacing fireplaces or other floor mounted heating, our floor consoles provide easy, efficient and quiet heating or cooling.

Quiet Operation

With operation from a hushed 22dBA, our floor consoles deliver the same whisper quiet operation that you have come to expect from Mitsubishi Electric.

Cleaner, Healthier Air

With Catechin and Anti-Allergy Enzyme filter technology, air is effectively deodorised and there is significant reduction in allergen and bacteria levels.The Anti-Allergy filter traps and breaks down dust mites, pollen and other airborne allergens ensuring cleaner, healthier air.

MFZ-KA50VA-A4 - DC Inverter Compact Floor Console

· Function: Cooling/Heating · Type: Single Split, Inverter
· Capacity - Cooling: 4.8 kW · Capacity - Heating: 6.0 kW
· Capacity - Cooling (min. - max.): 0.9 - 5.4 kW · Capacity - Heating (min. - max.): 0.9 - 7.9 kW
· Power input - Cooling: 1.55 kW · Power input - Heating: 1.86 kW
· Power input - Cooling (min. - max.): 0.19 - 1.98 kW · Power input - Heating (min. - max.): 0.19 - 2.81 kW
· Star rating - Cooling: 1.5 · Star rating - Heating: 2
· EER / COP: 3.28 / 3.34 · AEER / ACOP: 3.21 / 3.28
· Previous Star rating: 4.5 / 4.0 · Sensible - Cooling: 2.94 kW
· Dry Mode (Moisture Removal, Litre/hr): 2.5
· H2 Capacity - Heating*: 5.53 kW · H2 Power input - Heating*: 1.79 kW
· H2 COP - Heating*: 3.09
· Operation Range - Cooling: -10 / +43 degC · Operation Range - Heating: -15 / +24 degC
· Sound Level - Cooling (Low - Super High, dB(A)): 32 / 35 / 39 / 43 · Sound Level - Heating (Low - Super High, dB(A)): 32 / 35 / 39 / 44
· Current - Cooling [In+Outdoor] (Rated / Max.): 7.0 / 16.2 A · Current - Heating [In+Outdoor] (Rated / Max.): 8.5 / 16.2 A
· Air volume - Cooling (Super High, Litre/sec): 178 · Air volume - Heating (Super High, Litre/sec): 197
· Refrigerant: R410A · Liquid pipe size (OD, mm): 6.35
· Gas pipe size (OD, mm): 12.7 · Max. pipe length (m): 30
· Max. pipe height (m): 30 · Power supply: 230V +/- 10% / Single Phase / 50 Hz
· Dimensions (WxDxH, mm): 700 x 200 x 600 · Weight: 14 kg
· *Note: H2 is approximate (calculated data only)

SUZ-KA50VA2.TH-A - DC Inverter Outdoor Unit

· Function: Cooling/Heating · Type: Single Split, Standard Inverter
· Operation Range - Cooling: -15 / +43 degC · Operation Range - Heating: -15 / +24 degC
· Sound Level - Cooling (dB(A)): 53 · Sound Level - Heating (dB(A)): 55
· Air volume - Cooling (Litre/sec): 818 · Air volume - Heating (Litre/sec): 818
· Power supply: 240V +/- 10% / Single Phase / 50 Hz · Refrigerant: R410A
· Liquid pipe size (OD, mm): 6.35 · Gas pipe size (OD, mm): 12.7
· Max. pipe length (m): 30 · Max. pipe height (m): 30
· Dimensions (WxDxH, mm): 840 x 330 x 850 · Weight: 53 kg

·  Rating Conditions (AS / NZS 3823):
   Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB.     Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

·  Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

·  Dry function will not work when the room temperature is below 13°C.<

·  Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

·  Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

·  Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
   EER = Energy Efficiency Ratio
   COP = Coefficient of Performance
   AEER# = Annual Energy Efficiency Ratio
   ACOP# = Annual Coefficient of Performance
   #These include standby power in the rating calculation

Downloads

MFZ-KA50VA-A4

Other

Warranty

PAR-21MAA
Our PAR21, wired LCD seven day controller allows you to program up to eight separate start/stop patterns per day over a week.
PAR-30
Our PAR31 wired seven day controller with backlit LCD screen allows you to program up to eight separate start/stop patterns per day over a week.
MAC-333IF-E
MA, M-NET and Contact Terminal Interface. Has remote on/off, prohibit/permit control and run/error outputs - all outputs require an independent external 12VDC power supply. Used to connect PAR-21 / PAR-31 to; MSZ-GE/FB/EF, MFZ-KA/FB & SLZ-KA~VAL indoor units or a Central / Schedule Controller to each indoor unit connected to a M or S-Series outdoor unit.

Connect multiple indoor units to a single outdoor unit.

This system gives you the freedom to select the indoor model best suited to each and every room in your home. Multi-Split Systems are designed to allow multiple indoor units of varying capacity and type to be connected to just one outdoor unit, enhancing exterior aesthetics by reducing the number of outdoor units required.

MFZ-KA50VA Indoor Unit can be connected to the following Multi Room Systems.

MXZ-3C54VA
Multi-Split system outdoor unit. (WxDxH, mm): 840 x 330 x 710. Cooling/Heating capacity: 5.4/7.0kW. Weight: 57kg. Liquid / Gas Pipe (OD, mm): 6.35 x3 / 9.52 x3. Requires a minimum combination of 1 and a maximum of 3 indoor units (up to Class 50), with max. class total of 100.
MXZ-4C71VA
Multi-Split system outdoor unit. (WxDxH, mm): 840 x 330 x 710. Cooling/Heating capacity: 7.1/8.6kW. Weight: 58kg. Liquid / Gas Pipe (OD, mm): 6.35 x4 / 9.52 x3 + 12.7 x1. Requires a minimum combination of 1 and a maximum of 4 indoor units (up to Class 60), with max. class total of 125.
MXZ-4B80VA-A1
Multi-Split system outdoor unit. (WxDxH, mm): 900 x 320 x 900. Cooling/Heating capacity: 8.0/9.4kW. Weight: 67kg. Liquid / Gas Pipe (OD, mm): 6.35 x4 / 9.52 x3 + 12.7 x1. Requires a minimum combination of 1 and a maximum of 4 indoor units (up to Class 71), with max. class total of 145. Note: The MXZ-4C80VA can only use 1x class 71 indoor.
MXZ-5C100VA
Multi-Split system outdoor unit. (WxDxH, mm): 900 x 320 x 900. Cooling/Heating capacity: 10.0/12.0kW. Weight: 68kg. Liquid / Gas Pipe (OD, mm): 6.35 x5 / 9.52 x4 + 12.7 x1. Requires a minimum combination of 1 and a maximum of 5 indoor units (up to Class 71), with max. class total of 171.
MXZ-6C120VA-A1
Multi-Split system outdoor unit. (WxDxH, mm): 900 x 320 x 1070. Cooling/Heating capacity: 12.0/14.0kW. Weight: 68kg. Liquid / Gas Pipe (OD, mm): 6.35 x6 / 9.52 x5 + 12.7 x1. Requires a minimum combination of 1 and a maximum of 6 indoor units (up to Class 80), with max. class total of 180.
MXZ-8B140VA
Multi-Split system outdoor unit. (WxDxH, mm): 950 x 330 x 1350. Cooling/Heating capacity: 14.0/16.0kW. Weight: 129kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 71), with max. class total of 185. Central Branch Box(s): Two Branch boxes required if installing more than 5 indoors with Brazing Tee for dual Branch Box Connection.
MXZ-8B160VA
Multi-Split system outdoor unit. (WxDxH, mm): 950 x 330 x 1350. Cooling/Heating capacity: 15.5/18.0kW. Weight: 139kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 202. Central Branch Box(s): Two Branch boxes required if installing more than 5 indoors with Brazing Tee for dual Branch Box Connection. To connect to a 10.0kW indoor unit a Y-Connector is needed.
*Actual price may differ. Excludes install costs.