Suspended PCA50 Heat Pump

Medium Room System // PCA-RP50KAQ

Our Suspended PCA50 high performance heat pump is designed for style and efficiency. With four speed settings and auto air-speed adjustment it is ideal for mid-sized areas. Comes standard with a Classic PAR21 wired weekly controller and are able to precisely control power consumption and temperature, setting up to eight patterns per day.

Cooling Capacity5.0 kW
Heating Capacity5.5 kW
$3,879.99
RRP and excludes install costs*
Select a Size






Select a Contoller


Stylish Design

Sharp, clean lines make this unit blend in more easily with your ceiling, providing low-profile heating or cooling.

Automatic Air Speed Adjustment

In addition to the conventional 4-speed setting, our suspended units are now equipped with an automatic air-speed adjustment mode. This setting automatically adjusts the air speed to match the room environment. At the start of heating or cooling operation, the airflow is set to high-speed to quickly heat or cool the room. When the room temperature reaches your desired setting, the airflow speed is decreased automatically for stable comfortable heating or cooling operation.

Fresh Air Intake Option

Units are equipped with an opening that enables the induction of fresh outside air.

PAR21 Weekly Controller

With liquid crystal display technology and large screen, you are able to establish your unit’s operation status at a glance. You can set up to 8 temperature and airflow patterns per day for seven days, allowing you to reduce your energy consumption when needed, saving you both time and money. Perfect for the busy home and office or retail store.
Click here to find out more

Additional features:

PCA-RP50KAQ - Power Inverter Ceiling Suspended

· Function: Cooling/Heating · Type: Single Split, Power Inverter
· Capacity - Cooling: 5.0 kW · Capacity - Heating: 5.5 kW
· Capacity - Cooling (min. - max.): 1.1 - 5.6 kW · Capacity - Heating (min. - max.): 0.9 - 6.6 kW
· Power input - Cooling: 1.66 kW · Power input - Heating: 1.71 kW
· EER - Cooling: 3.01 · COP - Heating: 3.22
· Operation Range - Cooling: -15 / +43 degC · Operation Range - Heating: -15 / +24 degC
· Airflow (Lo-Mi1-Mi2-Hi, Litre/sec): 167-183-217-250 · Sound Level (Lo-Mi1-Mi2-Hi, dB(A)): 32-34-37-40
· Current Indoor - Cooling (Running / Starting): 0.37 / 1.20 A · Current Indoor - Heating (Running / Starting): 0.37 / 1.20 A
· Power supply: 230V +/- 10% / Single Phase / 50 Hz · Refrigerant: R410A
· Liquid pipe size (OD, mm): 6.35 · Gas pipe size (OD, mm): 12.7
· Max. pipe length (m): 30 · Max. pipe height (m): 15
· Dimensions (WxDxH, mm): 960 x 680 x 230 · Weight: 25 kg

Technical Note for: PAR-21MAA
Can be connected to the following indoor units: MSZ-GE/FB~VA*, MFZ-KA~VA* or MSZ-FB/MFZ-FB~VAH*. *Note: Requires a MAC-397IF-E adaptor. (The PAR-21MAA comes as a choice with: SLZ-KA~VAQ, SEZ-KD~VAQ, PLA-RP~BA, PEA-RP~EA, PCA-RP~KAQ indoor units.) Older models may be connectable, refer to manual.

SUZ-KA50VA3.TH-A - DC Inverter Outdoor Unit

· Function: Cooling/Heating · Type: Single Split, Standard Inverter
· Operation Range - Cooling: -15 / +43 degC · Operation Range - Heating: -15 / +24 degC
· Sound Level - Cooling (dB(A)): 53 · Sound Level - Heating (dB(A)): 55
· Air volume - Cooling (Litre/sec): 818 · Air volume - Heating (Litre/sec): 818
· Power supply: 240V +/- 10% / Single Phase / 50 Hz · Refrigerant: R410A
· Liquid pipe size (OD, mm): 6.35 · Gas pipe size (OD, mm): 12.7
· Max. pipe length (m): 30 · Max. pipe height (m): 30
· Dimensions (WxDxH, mm): 840 x 330 x 850 · Weight: 53 kg

·  Rating Conditions (AS / NZS 3823):
   Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB.     Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

·  Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

·  Dry function will not work when the room temperature is below 13°C.<

·  Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

·  Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

·  Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
   EER = Energy Efficiency Ratio
   COP = Coefficient of Performance
   AEER# = Annual Energy Efficiency Ratio
   ACOP# = Annual Coefficient of Performance
   #These include standby power in the rating calculation

PAC-SG59SG-E
This air outlet guide, used to force air vertically out of the outdoor unit, can be used to prevent the outdoor unit from short cycling the exhaust air. It also enables the outdoor unit to be mounted closer to a wall or other outdoor units and enables them to operate at -15°C in cooling mode.

Connect multiple indoor units to a single outdoor unit.

This system gives you the freedom to select the indoor model best suited to each and every room in your home. Multi-Split Systems are designed to allow multiple indoor units of varying capacity and type to be connected to just one outdoor unit, enhancing exterior aesthetics by reducing the number of outdoor units required.

PCA-RP50KAQ Indoor Unit can be connected to the following Multi Room Systems.

MXZ-3C54VA
Multi-Split system outdoor unit. (WxDxH, mm): 840 x 330 x 710. Cooling/Heating capacity: 5.4/7.0kW. Weight: 57kg. Liquid / Gas Pipe (OD, mm): 6.35 x3 / 9.52 x3. Requires a minimum combination of 1 and a maximum of 3 indoor units (up to Class 50), with max. class total of 100.
MXZ-4C71VA
Multi-Split system outdoor unit. (WxDxH, mm): 840 x 330 x 710. Cooling/Heating capacity: 7.1/8.6kW. Weight: 58kg. Liquid / Gas Pipe (OD, mm): 6.35 x4 / 9.52 x3 + 12.7 x1. Requires a minimum combination of 1 and a maximum of 4 indoor units (up to Class 60), with max. class total of 125.
MXZ-4B80VA-A1
Multi-Split system outdoor unit. (WxDxH, mm): 900 x 320 x 900. Cooling/Heating capacity: 8.0/9.4kW. Weight: 67kg. Liquid / Gas Pipe (OD, mm): 6.35 x4 / 9.52 x3 + 12.7 x1. Requires a minimum combination of 1 and a maximum of 4 indoor units (up to Class 71), with max. class total of 145. Note: The MXZ-4C80VA can only use 1x class 71 indoor.
MXZ-5C100VA
Multi-Split system outdoor unit. (WxDxH, mm): 900 x 320 x 900. Cooling/Heating capacity: 10.0/12.0kW. Weight: 68kg. Liquid / Gas Pipe (OD, mm): 6.35 x5 / 9.52 x4 + 12.7 x1. Requires a minimum combination of 1 and a maximum of 5 indoor units (up to Class 71), with max. class total of 171.
MXZ-6C120VA-A1
Multi-Split system outdoor unit. (WxDxH, mm): 900 x 320 x 1070. Cooling/Heating capacity: 12.0/14.0kW. Weight: 68kg. Liquid / Gas Pipe (OD, mm): 6.35 x6 / 9.52 x5 + 12.7 x1. Requires a minimum combination of 1 and a maximum of 6 indoor units (up to Class 80), with max. class total of 180.
*Actual price may differ. Excludes install costs.