Ducted PEAD 100 Heat Pump

Large Room System // PEAD-RP100JAA

Our low profile ducted PEAD 100 has a wide range of static pressures, that allows airflow to be directed to different areas of your home or office with ease. This unit is ideal for heating or cooling a number of rooms. Comes standard with a Deluxe PAR31 wired Controller, with backlit LCD display and user friendly menus. With the PAR31 you are able to precisely control power consumption and temperature, setting up to eight patterns per day.

Cooling Capacity10.0 kW
Heating Capacity11.2 kW
$7,959.99
RRP and excludes install costs*
Select a Size




Low Profile Design

Our low profile ducted systems at 250mm in height are specifically designed for installation in tight ceiling spaces.

Wide Range of Static Pressures with 3 Fan Speeds

Selectable external static pressure of 35, 50, 70, 100 and 125 Pa with 3 fan speeds allowing a wide range of installation possibilities.

Deluxe PAR31 Weekly Controller

This attractive full dot liquid crystal display incorporates a large backlit screen and simple menus for easy operation. You can set up to 8 temperature and airflow patterns per day for seven days, allowing you to reduce your energy consumption when need
Click here to find out more

PEAD-RP100JAA - Power Inverter Ceiling-Concealed

· Function: Cooling/Heating · Type: Single Split, Inverter
· Capacity - Cooling: 10.0 kW · Capacity - Heating: 11.2 kW
· Capacity - Cooling (min. - max.): 4.9 - 11.4 kW · Capacity - Heating (min. - max.): 4.5 - 14.0 kW
· Power input - Cooling: 2.77 kW · Power input - Heating: 2.72 kW
· EER - Cooling: 3.61 · COP - Heating: 4.12
· Operation Range - Cooling: -5 (-15*) / +46 degC · Operation Range - Heating: -20 / +21 degC
· Airflow (Lo-Hi, Litre/sec): 400-483-567 · Sound Level (Lo-Hi, dB(A)): 33-38-42
· Current Indoor - Cooling (Running): 1.57 A · Current Indoor - Heating (Running): 1.57 A
· Power supply: 230V +/- 10% / Single Phase / 50 Hz · Refrigerant: R410A
· Liquid pipe size (OD, mm): 9.52 · Gas pipe size (OD, mm): 15.88
· Max. pipe length (m): 75 · Max. pipe height (m): 30
· Dimensions (WxDxH, mm): 1,400 x 732 x 250 · Weight: 38 kg
· External Static Pressure: 35-50-70-100-125 Pa · Note: Capacity ratings are based on the outdoor unit PUHZ-RP100VKA2 only.
· [*]: -15 degC in cooling when using an optional outdoor air outlet guide PAC-SG59SG-E.

Technical Note for: PAR-31MAAE-J
Can be connected to the following indoor units: MSZ-GE/FB~VA*, MSZ-EF~VE*, MFZ-KA~VA* or MSZ-FB/MFZ-FB~VAH*. *Note: Requires either a MAC-333IF-E or MAC-397IF-E adaptor.

PUHZ-RP100VKA2-A - DC Deluxe Inverter Outdoor Unit

· Function: Cooling/Heating · Type: Single Split or Multi Split, Power Inverter
· Multi-Split System Compatible: Yes (50:50 Split) · Number of indoor units: 1 or 2
· Capacity - Cooling: 10.0 kW · Capacity - Heating: 11.2 kW
· Capacity - Cooling (min. - max.): 4.9 - 11.4 kW · Capacity - Heating (min. - max.): 4.5 - 14.0 kW
· Operation Range - Cooling: -5 (-15*) / +46 degC · Operation Range - Heating: -20 / +21 degC
· Sound Level - Cooling (dB(A)): 49 · Sound Level - Heating (dB(A)): 51
· Airflow (Litre/sec): 1830 · Current - Cooling Outdoor (Rated / Max.): 12.64 / 26.5 A
· Current - Heating Outdoor (Rated / Max.): 13.58 / 26.5 A · Power supply: 230V +/- 10% / Single Phase / 50 Hz
· Refrigerant: R410A · Liquid pipe size (OD, mm): 9.52
· Gas pipe size (OD, mm): 15.88 · Max. pipe length (m): 75
· Max. pipe height (m): 30 · Dimensions (WxDxH, mm): 1050 x 330(+30) x 1338
· Weight: 118 kg · [*]: -15°C in cooling when using an optional outdoor air outlet guide PAC-SG59SG-E.

·  Rating Conditions (AS / NZS 3823):
   Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB.     Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

·  Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

·  Dry function will not work when the room temperature is below 13°C.<

·  Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

·  Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

·  Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
   EER = Energy Efficiency Ratio
   COP = Coefficient of Performance
   AEER# = Annual Energy Efficiency Ratio
   ACOP# = Annual Coefficient of Performance
   #These include standby power in the rating calculation

Connect multiple indoor units to a single outdoor unit.

This system gives you the freedom to select the indoor model best suited to each and every room in your home. Multi-Split Systems are designed to allow multiple indoor units of varying capacity and type to be connected to just one outdoor unit, enhancing exterior aesthetics by reducing the number of outdoor units required.

PEAD-RP100JAA Indoor Unit can be connected to the following Multi Room Systems.
MXZ-8B160VA
Multi-Split system outdoor unit. (WxDxH, mm): 950 x 330 x 1350. Cooling/Heating capacity: 15.5/18.0kW. Weight: 139kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 202. Central Branch Box(s): Two Branch boxes required if installing more than 5 indoors with Brazing Tee for dual Branch Box Connection. To connect to a 10.0kW indoor unit a Y-Connector is needed.
*Actual price may differ. Excludes install costs.