Central Ducted Heating and Ventilation

8 Specifications: Fresh Air Home Ventilation Type In-Ceiling Concealed Ducted Model LGH-15RVX3-E LGH-25RVX3-E LGH-35RVX3-E LGH-50RVX3-E Ventilation Modes Energy Recovery Mode, Bypass Ventilation Mode Energy Recovery Mode, Bypass Ventilation Mode Energy Recovery Mode, Bypass Ventilation Mode Energy Recovery Mode, Bypass Ventilation Mode Heat Exchange System Energy Recovery Ventilation System Energy Recovery Ventilation System Energy Recovery Ventilation System Energy Recovery Ventilation System Heat Exchange Material Specially Treated Paper Plate Heat Exchanger Specially Treated Paper Plate Heat Exchanger Specially Treated Paper Plate Heat Exchanger Specially Treated Paper Plate Heat Exchanger Surrounding Air Condition Between 0°C and 40°C, 80%RH or less Between 0°C and 40°C, 80%RH or less Between 0°C and 40°C, 80%RH or less Between 0°C and 40°C, 80%RH or less Return (Suction) Air Condition Up to 40°C, 80%RH Up to 40°C, 80%RH Up to 40°C, 80%RH Up to 40°C, 80%RH Supply Fan Operation Under Low Outdoor Temperature -10°C to -15°C: Intermittent opperation 60 min ON, 10 min OFF. -15°C or less: Intermittent operation 55 min OFF, 5 min ON. -10°C to -15°C: Intermittent opperation 60 min ON, 10 min OFF. -15°C or less: Intermittent operation 55 min OFF, 5 min ON. -10°C to -15°C: Intermittent opperation 60 min ON, 10 min OFF. -15°C or less: Intermittent operation 55 min OFF, 5 min ON. -10°C to -15°C: Intermittent opperation 60 min ON, 10 min OFF. -15°C or less: Intermittent operation 55 min OFF, 5 min ON. Electrical Power Supply 220-240V / 50Hz 220-240V / 50Hz 220-240V / 50Hz 220-240V / 50Hz Fan Speed Fan Speed: High Fan Speed: Low Fan Speed: High Fan Speed: Low Fan Speed: High Fan Speed: Low Fan Speed: High Fan Speed: Low Input Power (W) 55 10 75 11 120 15 185 15 Air Volume - Heat Recovery Mode (m3/h) 150 38 250 63 350 88 500 125 (L/s) 42 10 69 17 97 24 139 35 External Static Pressure (Pa) 120 8 120 8 160 10 150 10 Temperature Exchange Efficiency (%) 73.5 81.5 75.5 88.0 75.0 82.0 70.5 75.0 Noise (dBA) (Measured at 1.5m under the centre o f the unit in an anechoic chamber) 27.0 17.0 30.5 17.0 30.5 17.0 35.0 17.0 Duct Size (mm) 100 150 150 200 Interlock Cable Included (CN2L) Yes Yes Yes Yes Dimensions W x D x H (mm) 780 x 610 x 289 780 x 735 x 289 888 x 874 x 331 888 x 1016 x 331 Weight (kg) 20 22 30 33 Note: Other models of the LGH Range are available (air volume from 38–2,000 m3/h). LGH Whole Home Range Lossnay VL100 Single Room Range Specifications: Single Room Ventilation Type Wall Mounted Single Room In-Ceiling Single Room Model VL-100EU5-E VL-100ZSKRT-E Ventilation Modes Energy Recovery Mode Energy Recovery Mode Heat Exchange System Energy Recovery Ventilation System Energy Recovery Ventilation System Heat Exchange Material Specially Treated Paper Plate Heat Exchanger Specially Treated Paper Plate Heat Exchanger Surrounding Air Condition Between -10°C and 40°C, 80%RH or less Between -10°C and 40°C, 80%RH or less Return (Suction) Air Condition Up to 40°C, 80%RH Up to 40°C, 80%RH Electrical Power Supply 230V / 50Hz 230V / 50Hz Fan Speed Fan Speed: High Fan Speed: Low Fan Speed: High Fan Speed: Low Input Power (W) 31 15 32 15 Air Volume - Heat Recovery Mode (m3/h) 105 60 78 42 (L/s) 29.1 16.6 21.7 11.7 Temperature Exchange Efficiency (%)* 73 80 49 62 Noise (dBA) (Measured at 1.5m under the centre o f the unit in an anechoic chamber) 37 25 40 25.5 Duct Size (mm) - 100 Dimensions W x D x H (mm) 620 x 200 x 265 Unit: 386 x 386 x 204 Grille: 455 x 455 x 9 Weight (kg) 7.5 6 *In heating mode PUBLISHED APR 2024 www.mitsubishi-electric.co.nz | 0800 784 382 Please note: When deciding on the best place to position the Lossnay Ventilation System, care needs to be taken to not have incoming air intake near or close to a wood burner flue.

RkJQdWJsaXNoZXIy MTg0ODUyNA==