Specifications: PEA-GAA Ducted Series Refrigerant R32 Indoor Unit PEA-M100GAA PEA-M125GAA PEA-M140GAA Outdoor Unit (Standard, Deluxe) PUZ-M100VKA PUZ-ZM100VKA2 PUZ-M125VKA PUZ-ZM125VKA2 PUZ-M140VKA PUZ-ZM140VKA2 Function Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Capacity (min.–max.) (kW) 10.0 (4.0-10.6) 12.5 (2.8-12.5) 10.0 (4.9-11.4) 11.2 (4.5-14.0) 12.0 (6.0-13.5) 14.0 (4.1-15.5) 12.5 (5.5-14.0) 14.0 (5.0-16.0) 14.0 (6.2-15.3) 16.0 (5.7-18.0) 14.0 (6.2-15.3) 16.0 (5.7-18.0) Power Input (kW) 3.08 3.36 2.39 2.51 3.81 3.54 3.52 3.27 4.22 4.20 4.10 3.90 Rated EER/COP 3.24 3.72 4.18 4.46 3.14 3.95 3.55 4.28 3.31 3.80 3.41 4.10 Rated AEER/ACOP 3.12 3.58 4.01 4.29 3.04 3.81 3.45 4.15 3.22 3.69 3.33 3.99 Power Supply 230V, Single-phase, 50Hz Airflow (Lo–Hi) m3/min 34-42 48-60 L/S 567-700 800-1000 Indoor Sound Pressure Level (dB) 33-38-42 39-42 42-45 External Static Pressure (Pa) 50 / 100 / 150 Dimensions Height (mm) 400 Width (mm) 1,400 Depth (mm) 634 Indoor Unit Weight (kg) 63 Refrigerant Piping Max. Length/Height 55 / 30 75 / 30 55 / 30 75 / 30 55 / 30 75 / 30 Operation Range Outdoor Cooling (°C) -5(-15*2) ~ 46 -5(-15*2) ~ 52 -5(-15*2) ~ 46 -5(-15*2) ~ 52 -5(-15*2) ~ 46 -5(-15*2) ~ 52 Heating (°C) -15 ~ 21 -20 ~ 21 -15 ~ 21 -20 ~ 21 -15 ~ 21 -20 ~ 21 *2 With optional air protection guide. Refer to page 20 for outdoor specifications. Optional Zone Controller The optional Zone Controller brings intuitive yet simple control to a whole new level, with the ability to control up to eight zones, automatic unloading/ramping and energy saving sensor functions. Optional Wi-Fi Interlock for Total Home Control Seamlessly combine a Mitsubishi Electric Mr Slim Ducted Heat Pump and Lossnay Heat Recovery Ventilation System through the Wi-Fi Control App for the ultimate visibility and control. Because the Ducted Heat Pump needs to be in fan, heating or cooling mode for the connected Lossnay system to operate, you can now choose from two innovative modes to customise the climate control setup. Use the “Power Interlock” mode, to enjoy set and forget convenience. In this mode, both systems will always automatically activate together no matter which system you initially turn on. Opt for “Fresh Air Fan Interlock” mode to prioritise fresh air circulation; regardless of whether the ducted system is turned on. In this mode, the Lossnay System will override a ducted system that is turned off and automatically activate the system’s Fan Mode. As a result fresh air continues to efficiently circulate throughout the building. Note: Each unit requires its own Wi-Fi Interface to enable Wi-Fi Interlock Control. 9
RkJQdWJsaXNoZXIy MTg0ODUyNA==