The MLZ-35 one-way cassette for multi-split connection, with its streamlined design, advanced airflow control and quiet operation from just 26dBA, is ideal for small installation spaces. With the ability to adjust airflow according to ceiling height and direction, and with horizontal airflow, uncomfortable draughts are a thing of the past.

Cooling Capacity3.5 kW
Heating Capacity4.0 kW
Select a Size
Select a Contoller

Features

Multi Room Connection Only

The MLZ Series is for multi split connection only. A multi room system allows you to connect multiple indoor units to a single outdoor unit. This system not only gives you the freedom to select the indoor model best suited to each and every room in your home, it also enhances exterior aesthetics by reducing the number of outdoor units required.

Auto Vane Control

Outlet vanes can be moved left and right when in Econo Cool mode, and up and down, using the remote controller; elimating draughts and enhancing room comfort.

One-way Airflow

Ideal for rooms where one-way air distribution is required, and a solution for spaces where lighting fixtures are installed in the centre of a room, one-way airflow provides a comofrtable environment with no draughts.

Compact Design

Our ceiling cassettes are New Zealand’s favourite. With the lightweight unit sitting in your ceiling space, only the grille is visible providing easy, discreet installation into your home or office.

Horizontal Airflow

Advanced horizontal airflow eliminates uncomfortable draughts and improves airflow control. Six different discharge angles provide a lateral airflow advantage; ensuring air is evenly distributed across your entire room.

Quiet Operation

Starting from a hushed 26dBA, our MLZ Cassette Series is the perfect solution for quiet comfort; allowing you to feel the warmth, not hear it.

Air Purifying Filter

This built-in filter removes dust and other particles, keeping the air clean all the time. Maintenance is as simple as vacuuming.

Specifications

MLZ-KP35VF-A1 - One-way MLZ-KP35 Cassette

· Function: Cooling/Heating · Type: Indoor for Multi-Split System
· Capacity - Cooling: 3.5 kW · Capacity - Heating: 4.0 kW
· Sound Level - Cooling (Quiet - Super High, dB(A)): 27/32/36/40 · Sound Level - Heating (Quiet - Super High, dB(A)): 26/32/36/40
· Operating current (A): 0.4 · Air volume - Cooling (Super High, Litre/sec): 157
· Air volume - Heating (Super High, Litre/sec): 165 · Refrigerant: R410A/R32
· Liquid pipe size (OD, mm): 6.35 · Gas pipe size (OD, mm): 9.52
· Power supply: 230V / Single Phase / 50 Hz · Dimensions (WxDxH, mm): 1102 x 360 x 185
· Weight: 15.5 kg · Panel Dimensions (WxDxH, mm): 1,200 x 424 x 24
· Panel Weight: 3.5 kg

·  Rating Conditions (AS / NZS 3823):
   Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB.     Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

·  Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

·  Dry function will not work when the room temperature is below 13°C.

·  Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

·  Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

·  Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
   EER = Energy Efficiency Ratio
   COP = Coefficient of Performance
   AEER# = Annual Energy Efficiency Ratio
   ACOP# = Annual Coefficient of Performance
   #These include standby power in the rating calculation

Downloads

Support

Optional

Connect multiple indoor units to a single outdoor unit.

This system gives you the freedom to select the indoor model best suited to each and every room in your home. Multi-Split Systems are designed to allow multiple indoor units of varying capacity and type to be connected to just one outdoor unit, enhancing exterior aesthetics by reducing the number of outdoor units required.

MLZ-KP35VF-A1 Indoor Unit can be connected to the following Multi Room Systems.

Multi-Split system outdoor unit. (WxDxH, mm): 800 x 285 x 550. Cooling/Heating capacity: 5.2/6.1kW. Weight: 37kg. Liquid / Gas Pipe (OD, mm): 6.35 x2 / 9.52 x2. Either a minimum of 1 or maximum combination 2 indoor units (up to Class 50), with max. class total of 75.
Multi-Split system outdoor unit. (WxDxH, mm): 840 x 330 x 710. Cooling/Heating capacity: 5.4/7.0kW. Weight: 58kg. Liquid / Gas Pipe (OD, mm): 6.35 x3 / 9.52 x3. Requires a minimum combination of 2 and a maximum of 3 indoor units (up to Class 50), with max. class total of 100.
Multi-Split system outdoor unit. (WxDxH, mm): 840 x 330 x 710. Cooling/Heating capacity: 7.1/8.0kW. Weight: 59kg. Liquid / Gas Pipe (OD, mm): 6.35 x4 / 9.52 x3 + 12.7 x1. Requires a minimum combination of 2 and a maximum of 4 indoor units (up to Class 60), with max. class total of 125.
Multi-Split system outdoor unit. (WxDxH, mm): 950x 330 x 796. Cooling/Heating capacity: 8.0/8.8kW. Weight: 63kg. Liquid / Gas Pipe (OD, mm): 6.35 x4 / 9.52 x3 + 12.7 x1. Requires a minimum combination of 2 and a maximum of 4 indoor units (up to Class 71), with max. class total of 145.
Multi-Split system outdoor unit. (WxDxH, mm): 9500 x 330 x 796. Cooling/Heating capacity: 10.0/10.0kW. Weight: 64kg. Liquid / Gas Pipe (OD, mm): 6.35 x5 / 9.52 x4 + 12.7 x1. Requires a minimum combination of 2 and a maximum of 5 indoor units (up to Class 71), with max. class total of 171.
Multi-Split system outdoor unit. (WxDxH, mm): 1050 x 330(25) x 981. Cooling/Heating capacity: 12.5/14.0kW. Weight: 93kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 162. Central Branch Box(s): When installing two Branch Boxes, use Brazing or Flare Tee for dual Branch Box Connection.
Multi-Split system outdoor unit. (WxDxH, mm): 1050 x 330(25) x 981. Cooling/Heating capacity: 14.0/16.0kW. Weight: 93kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 182. Central Branch Box(s): When installing two Branch Boxes, use Brazing or Flare Tee for dual Branch Box Connection.
Multi-Split system outdoor unit. (WxDxH, mm): 1050 x 330 x 981. Cooling/Heating capacity: 15.5/16.5kW. Weight: 93kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 202. Central Branch Box(s): When installing two Branch Boxes, use Brazing or Flare Tee for dual Branch Box Connection.