Our compact and ultra quiet SLZ25 cassette, fits neatly into your ceiling cavity leaving only the grille visible. Its low energy consumption, four way air distribution and versatile control make it ideal if you are looking to heat a smaller room in your home or office. This unit comes standard with infrared 24 hour remote.

Cooling Capacity2.3 kW
Heating Capacity3.1 kW
Select a Size
Select a Contoller

Features

Compact Design

Our ceiling cassettes are New Zealand’s favourite. With the lightweight unit sitting in your ceiling space, only the grille is visible providing easy, discreet installation into your home or office.

Multi Directional Airflow

With four-way air outlets, our cassettes provide maximum comfort by evenly distributing airflow throughout the area you need to heat or cool.

Air Cleaning Filtration

A built in filter removes dust and contaminants keeping air purified and deodorised. The washable, long-life filter can be used for up to 2,500 hours with simple maintenance.

Specifications

SLZ-KA25VALR2.TH - DC Inverter Compact Cassette

· Function: Cooling/Heating · Type: Single Split, Inverter
· Capacity - Cooling: 2.3 kW · Capacity - Heating: 3.1 kW
· Capacity - Cooling (min. - max.): 0.9 - 3.2 kW · Capacity - Heating (min. - max.): 0.9 - 4.5 kW
· Power input - Cooling: 0.68kW · Power input - Heating: 0.85 kW
· Star rating - Cooling: 2.5 · Star rating - Heating: 3.0
· EER / COP: 3.81 / 3.94 · Previous Star rating: 2.5 / 2.5
· AEER / ACOP: 3.64 / 3.81 · Sensible - Cooling: 2 06 kW
· Dry Mode (Moisture Removal, Litre/hr): 0.5
· Operation Range - Cooling: -10 / +46°C · Operation Range - Heating: -15 / +24°C
· Indoor Sound - Cooling (Low - High, dB(A)): 28 / 31 / 37 · Indoor Sound - Heating (Low - High, dB(A)): 28 / 31 / 37
· Current - Cooling [in+outdoor] (Rated / Max.): 3.4 / 8.16 A · Current - Heating [in+outdoor] (Rated / Max.): 4.0 / 8.16 A
· Air volume - Cooling (High, Litre/sec): 167 · Air volume - Heating (High, Litre/sec): 167
· Refrigerant: R410A · Liquid pipe size (OD, mm): 6.35
· Gas pipe size (OD, mm): 9.52 · Max. pipe length (m): 20
· Max. pipe height (m): 12 · Power supply: 230V +/- 10% / Single Phase / 50 Hz
· Panel Dimensions (WxDxH, mm): 650 x 650 x 20 · Panel Weight: 3kg
· Dimensions (WxDxH, mm): 570 x 570 x 235 · Weight: 16.5 kg

SUZ-KA25VAD.TH-A - DC Inverter Outdoor Unit

· Function: Cooling/Heating · Type: Single Split, Standard Inverter
· Operation Range - Cooling: -10 / +46°C · Operation Range - Heating: -15 / +24°C
· Sound Level - Cooling (dB(A)): 46 · Sound Level - Heating (dB(A)): 46
· Air volume - Cooling (Litre/sec): 568 · Air volume - Heating (Litre/sec): 534
· Power supply: 240V +/- 10% / Single Phase / 50 Hz · Refrigerant: R410A
· Liquid pipe size (OD, mm): 6.35 · Gas pipe size (OD, mm): 9.52
· Max. pipe length (m): 20 · Max. pipe height (m): 12
· Dimensions (WxDxH, mm): 800 x 285 x 550 · Weight: 30 kg

·  Rating Conditions (AS / NZS 3823):
   Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB.     Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

·  Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

·  Dry function will not work when the room temperature is below 13°C.

·  Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

·  Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

·  Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
   EER = Energy Efficiency Ratio
   COP = Coefficient of Performance
   AEER# = Annual Energy Efficiency Ratio
   ACOP# = Annual Coefficient of Performance
   #These include standby power in the rating calculation

Downloads

Support

Optional

Connect multiple indoor units to a single outdoor unit.

This system gives you the freedom to select the indoor model best suited to each and every room in your home. Multi-Split Systems are designed to allow multiple indoor units of varying capacity and type to be connected to just one outdoor unit, enhancing exterior aesthetics by reducing the number of outdoor units required.

SLZ-KA25VAL Indoor Unit can be connected to the following Multi Room Systems.

Multi-Split system outdoor unit. (WxDxH, mm): 800 x 285 x 550. Cooling/Heating capacity: 5.2/6.1kW. Weight: 37kg. Liquid / Gas Pipe (OD, mm): 6.35 x2 / 9.52 x2. Either a minimum of 1 or maximum combination 2 indoor units (up to Class 42), with max. class total of 75.
Multi-Split system outdoor unit. (WxDxH, mm): 840 x 330 x 710. Cooling/Heating capacity: 5.4/7.0kW. Weight: 58kg. Liquid / Gas Pipe (OD, mm): 6.35 x3 / 9.52 x3. Requires a minimum combination of 1 and a maximum of 3 indoor units (up to Class 50), with max. class total of 100.
Multi-Split system outdoor unit. (WxDxH, mm): 840 x 330 x 710. Cooling/Heating capacity: 7.1/8.0kW. Weight: 59kg. Liquid / Gas Pipe (OD, mm): 6.35 x4 / 9.52 x3 + 12.7 x1. Requires a minimum combination of 2 and a maximum of 4 indoor units (up to Class 60), with max. class total of 125.
Multi-Split system outdoor unit. (WxDxH, mm): 950x 330 x 796. Cooling/Heating capacity: 8.0/8.8kW. Weight: 63kg. Liquid / Gas Pipe (OD, mm): 6.35 x4 / 9.52 x3 + 12.7 x1. Requires a minimum combination of 1 and a maximum of 4 indoor units (up to Class 71), with max. class total of 145.
Multi-Split system outdoor unit. (WxDxH, mm): 950 x 330 x 796. Cooling/Heating capacity: 10.0/10.0kW. Weight: 64kg. Liquid / Gas Pipe (OD, mm): 6.35 x5 / 9.52 x4 + 12.7 x1. Requires a minimum combination of 2 and a maximum of 5 indoor units (up to Class 71), with max. class total of 171.
Multi-Split system outdoor unit. (WxDxH, mm): 950 x 330 x 1048. Cooling/Heating capacity: 12.0/13.2kW. Weight: 88kg. Liquid / Gas Pipe (OD, mm): 6.35 x6 / 9.52 x5 + 12.7 x1. Requires a minimum combination of 2 and a maximum of 6 indoor units (up to Class 80), with max. class total of 180.
Multi-Split system outdoor unit. (WxDxH, mm): 1050 x 330 x 1338. Cooling/Heating capacity: 14.0/16.0kW. Weight: 125kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 182. Central Branch Box(s): When installing two Branch Boxes, use Brazing or Flare Tee for dual Branch Box Connection.
Multi-Split system outdoor unit. (WxDxH, mm): 1050 x 330 x 1338. Cooling/Heating capacity: 15.5/18.0kW. Weight: 125kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 201. Central Branch Box(s): When installing two Branch Boxes, use Brazing or Flare Tee for dual Branch Box Connection.
Classic Cassette Series