Classic GE60 High Wall Heat Pump

Large Room System // MSZ-GE60VAD

Our Classic GE60 heat pump is designed for quietness, energy saving and elegance. Its high capacity makes it the perfect heat pump if you are looking to heat a large room or if you live in a frosty area and need a bit more power.

Cooling Capacity6.0 kW
Heating Capacity6.8 kW
Energy Star Approved
Select a Size
Select a Contoller

Features

7-Day Programmable Hand Held Controller

Advanced infrared controller allowing the programming of up to four settings (per 24 hour period) including start/stop operation and temperature settings over a 7 day period. This eliminates the need to reset the timer daily. You can program your heat pump to start up before you wake or return home and regulate your energy usage without compromising on comfort.

Energy Efficiency

The Energy Star mark is awarded to the most energy efficient heat pumps available in New Zealand which means better performance all winter long. The MSZ-GE60 has been awarded the Energy Star mark, signalling they meet strict energy efficiency standards.

Wide and Long Airflow

The Wide and Long Airflow modes allow the airflow direction to be adjusted, ensuring every corner of the room is comfortable. These modes are simply activated at the touch of a button on your remote controller. The Long Mode extends airflow by up to 12m to reach even the furthest point of large living rooms, or allows kitchens to be reached in an open plan environment.

Optional Wi-Fi Control Upgrade

With the addition of award winning Mitsubishi Electric Wi-Fi Control, you can control and monitor your heat pump from absolutely anywhere via your smartphone, tablet or online account.

Read more and try a demonstration

New Zealand's Quietest Heat Pumps

Specifications

MSZ-GE60VAD-A1 - DC Inverter Wall Mounted

· Function: Cooling/Heating · Type: Single Split, Inverter
· Capacity - Cooling: 6.0 kW · Capacity - Heating: 6.8 kW
· Capacity - Cooling (min. - max.): 1.5 - 7.5 kW · Capacity - Heating (min. - max.): 2.0 - 9.3 kW
· Power input - Cooling: 1.76 kW · Power input - Heating: 1.77 kW
· Star rating - Cooling: 2.5 · Star rating - Heating: 3
· EER / COP: 3.55 / 3.84 · AEER / ACOP: 3.51 / 3.80
· Previous Star rating: 2.0 / 3.0 · Sensible - Cooling: 4.70 kW
· Dry Mode (Moisture Removal, Litre/hr): 1.9 L
· Operation Range - Cooling: -10 / +46°C · Operation Range - Heating: -15 / +24°C
· Sound Level - Cooling (Quiet - Super High, dB(A)): 29 / 37 / 41 / 45 / 49 · Sound Level - Heating (Quiet - Super High, dB(A)): 29 / 37 / 41 / 45 / 49
· Current - Cooling [in+outdoor] (Rated / Max.): 7.8 / 14.5 A · Current - Heating [in+outdoor] (Rated / Max.): 7.8 / 14.5 A
· Air volume - Cooling (Super High, Litre/sec): 305 · Air volume - Heating (Super High, Litre/sec): 305
· Refrigerant: R410A · Liquid pipe size (OD, mm): 6.35
· Gas pipe size (OD, mm): 15.88 · Max. pipe length (m): 30
· Max. pipe height (m): 15 · Power supply: 230V / Single Phase / 50 Hz
· Dimensions (WxDxH, mm): 1100 x 238 x 325 · Weight: 16 kg

MUZ-GE60VAD-A1 - DC Inverter Outdoor Unit

· Function: Cooling/Heating · Type: Single Split, Standard Inverter
· Operation Range - Cooling: -10 / +46°C · Operation Range - Heating: -15 / +24°C
· Sound Level - Cooling (dB(A)): 55 · Sound Level - Heating (dB(A)): 55
· Air volume - Cooling (Litre/sec): 970 · Air volume - Heating (Litre/sec): 820
· Power supply: 230V / Single Phase / 50 Hz · Refrigerant: R410A
· Liquid pipe size (OD, mm): 6.35 · Gas pipe size (OD, mm): 15.88
· Max. pipe length (m): 30 · Max. pipe height (m): 15
· Dimensions (WxDxH, mm): 840 x 330 x 880 · Weight: 50 kg

·  Rating Conditions (AS / NZS 3823):
   Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB.     Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

·  Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

·  Dry function will not work when the room temperature is below 13°C.

·  Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

·  Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

·  Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
   EER = Energy Efficiency Ratio
   COP = Coefficient of Performance
   AEER# = Annual Energy Efficiency Ratio
   ACOP# = Annual Coefficient of Performance
   #These include standby power in the rating calculation

Downloads

Support

Optional

Optional Accessories

Our PAR32 wired seven day controller with backlit LCD screen allows you to program up to eight separate start/stop patterns per day over a week.
MA, M-NET and Contact Terminal Interface. Has remote on/off, prohibit/permit control and run/error outputs - all outputs require an independent external 12VDC power supply. Used to connect PAR-21 / PAR-31 to; MSZ-GE/FB/EF, MFZ-KA/FB & SLZ-KA~VAL indoor units or a Central / Schedule Controller to each indoor unit connected to a M or S-Series outdoor unit.

Connect multiple indoor units to a single outdoor unit.

This system gives you the freedom to select the indoor model best suited to each and every room in your home. Multi-Split Systems are designed to allow multiple indoor units of varying capacity and type to be connected to just one outdoor unit, enhancing exterior aesthetics by reducing the number of outdoor units required.

MSZ-GE60VAD Indoor Unit can be connected to the following Multi Room Systems.

Multi-Split system outdoor unit. (WxDxH, mm): 840 x 330 x 710. Cooling/Heating capacity: 7.1/8.0kW. Weight: 59kg. Liquid / Gas Pipe (OD, mm): 6.35 x4 / 9.52 x3 + 12.7 x1. Requires a minimum combination of 2 and a maximum of 4 indoor units (up to Class 60), with max. class total of 125.
Multi-Split system outdoor unit. (WxDxH, mm): 950x 330 x 796. Cooling/Heating capacity: 8.0/8.8kW. Weight: 63kg. Liquid / Gas Pipe (OD, mm): 6.35 x4 / 9.52 x3 + 12.7 x1. Requires a minimum combination of 1 and a maximum of 4 indoor units (up to Class 71), with max. class total of 145.
Multi-Split system outdoor unit. (WxDxH, mm): 950 x 330 x 796. Cooling/Heating capacity: 10.0/10.0kW. Weight: 64kg. Liquid / Gas Pipe (OD, mm): 6.35 x5 / 9.52 x4 + 12.7 x1. Requires a minimum combination of 2 and a maximum of 5 indoor units (up to Class 71), with max. class total of 171.
Multi-Split system outdoor unit. (WxDxH, mm): 950 x 330 x 1048. Cooling/Heating capacity: 12.0/13.2kW. Weight: 88kg. Liquid / Gas Pipe (OD, mm): 6.35 x6 / 9.52 x5 + 12.7 x1. Requires a minimum combination of 2 and a maximum of 6 indoor units (up to Class 80), with max. class total of 180.
Multi-Split system outdoor unit. (WxDxH, mm): 1050 x 330 x 1338. Cooling/Heating capacity: 14.0/16.0kW. Weight: 125kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 182. Central Branch Box(s): When installing two Branch Boxes, use Brazing or Flare Tee for dual Branch Box Connection.
Multi-Split system outdoor unit. (WxDxH, mm): 1050 x 330 x 1338. Cooling/Heating capacity: 15.5/18.0kW. Weight: 125kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 201. Central Branch Box(s): When installing two Branch Boxes, use Brazing or Flare Tee for dual Branch Box Connection.

Classic GE Series