Boasting the latest in technological innovation, the new Deluxe FH35 High Wall sets a new standard in high performance customised energy efficient comfort. This is the perfect heat pump if you are looking to heat a smaller room.
Exclusive to the FH Deluxe Series, the unique 3D "i-See" Sensor continuously analyses the temperature profile of your room, detecting exactly where you and your family are located based on your unique body heat signatures. With this thermal data, it then directs the perfect amount of heating or cooling towards those who need it most.
Dual Split Vane Technology
The split vane design on the FH Deluxe Series allows airflow to be customised to suit different areas of the room, by independently direct air upwards, downwards or to the side. Split vane airflow is ideal for multi level hallways in homes.
Natural Airflow
Natural Air Flow mode recreates a light and gentle natural breeze airflow by automatically modulating fan speed and direction. The overall effect, airflow that feels as natural as possible, enhancing total all round comfort
Plasma Quad Filtration
The Plasma Quad Filter System is an advanced, multi-stage filtration system designed to effectively neutralise contaminants such as allergens, viruses and bacteria whilst also neutralizing odours, ensuring the circulation of fresh, clean air back into the room. This level of advanced filtration system is ideal for those suffering from Asthma and other
airborne allergies.
6 Star Energy Efficiency
All models in the FH Deluxe High Wall Range have been awarded the Energy Star mark, making them some of the most energy efficient heat pumps available in New Zealand. The FH25 model even boasts a 6 Star Energy Rating ensuring super energy efficient performance all winter long.
Occupancy/Absence Detection
With a built in intuitive occupancy sensor, all FH Deluxe Series models able to detect when you leave the room (when in occupancy mode), automatically switching into energy-saving mode to realise even greater energy savings.
Optional Wi-Fi Control Upgrade
With the addition of award winning Mitsubishi Electric Wi-Fi Control, you can control and monitor your heat pump from absolutely anywhere via your smartphone, tablet or online account.
MA, M-NET and Contact Terminal Interface. Has remote on/off, prohibit/permit control and run/error outputs - all outputs require an independent external 12VDC power supply. Used to connect PAR-21 / PAR-31 to; MSZ-GE/FB/EF, MFZ-KA/FB & SLZ-KA~VAL indoor units or a Central / Schedule Controller to each indoor unit connected to a M or S-Series outdoor unit.
The award winning MAC-559IF-E Wi-Fi Interface connects discreetly to your heat pump’s control board and should only be installed by an authorised installer. The MAC-559IF-E Wi-Fi Interface is available on Mitsubishi Electric High Wall, Floor Mounted, and Ducted Heat Pumps, and can either be purchased as an optional upgrade at time of purchase, or retrofitted to an existing Mitsubishi Electric model.
Connect multiple indoor units to a single outdoor unit.
This system gives you the freedom to select the indoor model best suited to each and every room in your home. Multi-Split Systems
are designed to allow multiple indoor units of varying capacity and type to be connected to just one outdoor unit, enhancing exterior
aesthetics by reducing the number of outdoor units required.
MSZ-FH35VE Indoor Unit can be connected to the following Multi Room Systems.
Multi-Split system outdoor unit. (WxDxH, mm): 800 x 285 x 550. Cooling/Heating capacity: 5.2/6.1kW. Weight: 37kg. Liquid / Gas Pipe (OD, mm): 6.35 x2 / 9.52 x2. Either a minimum of 1 or maximum combination 2 indoor units (up to Class 42), with max. class total of 75.
Multi-Split system outdoor unit. (WxDxH, mm): 840 x 330 x 710. Cooling/Heating capacity: 5.4/7.0kW. Weight: 58kg. Liquid / Gas Pipe (OD, mm): 6.35 x3 / 9.52 x3. Requires a minimum combination of 1 and a maximum of 3 indoor units (up to Class 50), with max. class total of 100.
Multi-Split system outdoor unit. (WxDxH, mm): 840 x 330 x 710. Cooling/Heating capacity: 7.1/8.0kW. Weight: 59kg. Liquid / Gas Pipe (OD, mm): 6.35 x4 / 9.52 x3 + 12.7 x1. Requires a minimum combination of 2 and a maximum of 4 indoor units (up to Class 60), with max. class total of 125.
Multi-Split system outdoor unit. (WxDxH, mm): 950x 330 x 796. Cooling/Heating capacity: 8.0/8.8kW. Weight: 63kg. Liquid / Gas Pipe (OD, mm): 6.35 x4 / 9.52 x3 + 12.7 x1. Requires a minimum combination of 1 and a maximum of 4 indoor units (up to Class 71), with max. class total of 145.
Multi-Split system outdoor unit. (WxDxH, mm): 950 x 330 x 796. Cooling/Heating capacity: 10.0/10.0kW. Weight: 64kg. Liquid / Gas Pipe (OD, mm): 6.35 x5 / 9.52 x4 + 12.7 x1. Requires a minimum combination of 2 and a maximum of 5 indoor units (up to Class 71), with max. class total of 171.
Multi-Split system outdoor unit. (WxDxH, mm): 950 x 330 x 1048. Cooling/Heating capacity: 12.0/13.2kW. Weight: 88kg. Liquid / Gas Pipe (OD, mm): 6.35 x6 / 9.52 x5 + 12.7 x1. Requires a minimum combination of 2 and a maximum of 6 indoor units (up to Class 80), with max. class total of 180.
Multi-Split system outdoor unit. (WxDxH, mm): 1050 x 330 x 1338. Cooling/Heating capacity: 14.0/16.0kW. Weight: 125kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 182. Central Branch Box(s): When installing two Branch Boxes, use Brazing or Flare Tee for dual Branch Box Connection.
Multi-Split system outdoor unit. (WxDxH, mm): 1050 x 330 x 1338. Cooling/Heating capacity: 15.5/18.0kW. Weight: 125kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 201. Central Branch Box(s): When installing two Branch Boxes, use Brazing or Flare Tee for dual Branch Box Connection.