Power Inverter Ducted / Ceiling-Concealed

PEA-RP71EA

Ducted / ceiling-concealed indoor unit - inverter heat pump with wired PAR-21MAA 7 day wall timer. Cooling/Heating capacity: 7.1/8.0kW. (WxDxH, mm): 785 x 690 x 428. Weight: 46kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a PUHZ-RP71VHA outdoor unit or can be used in a customisable MXZ-4A/B/C80, 5A/B100, 6C120 or 8A140VA Multi-Split Systems, or PUHZ-RP140 Twin-Split System.

Discontinued Product

Specifications

· Function: Cooling/Heating · Type: Single Split, Inverter
· Capacity - Cooling: 7.1 kW · Capacity - Heating: 8.4 kW
· Capacity - Cooling (min. - max.): 3.3 - 8.1 kW · Capacity - Heating (min. - max.): 3.5 - 10.2 kW
· Power Input - Cooling: 2.48 kW · Power Input - Heating: 2.51 kW
· AEER - Cooling: 2.75 · ACOP - Heating: 3.20
· Operation Range - Cooling: -5 (-15*) / +46°C · Operation Range - Heating: -11 / +21°C
· Airflow (Lo-Hi, Litre/sec): 367-450 · Sound Level (Lo-Hi, dB(A)): 52-55
· Current Indoor - Cooling (Running): 1.66 A · Current Indoor - Heating (Running): 1.66 A
· Power Supply: 230V +/- 10% / Single Phase / 50 Hz · Refrigerant: R410A
· Liquid Pipe Size (OD, mm): 9.52 · Gas Pipe Size (OD, mm): 15.88
· Max. Pipe Length (m): 50 · Max. Pipe Height (m): 30
· Dimensions (WxDxH, mm): 785 x 690 x 428 · Weight: 46 kg
· External Static Pressure: 125 Pa · Note: Capacity ratings are based on the deluxe outdoor unit PUHZ-RP71VHA only.
· [*]: -15°C in cooling when using an optional outdoor air outlet guide PAC-SG59SG-E.