Classic AP 42 High Wall Heat Pump

Medium Room System // MSZ-AP42VGD2

The Classic AP42 High Wall Heat Pump sets a new standard in super energy efficient heating and cooling. With Dual Barrier Coating that prevents dust and dirt build-up on the inner surface, the Classic AP42 stays clean year-round; maximising efficiency and home comfort.

Cooling Capacity4.2 kW
Heating Capacity5.4 kW
Select a Size
Select a Controller

Features

Whisper Quiet

Starting from barely a whisper, the EcoCore AP Series ensures you only feel the warmth, not hear it! Furthermore, the addition of Night Mode means the outdoor operating noise level drops by a further 3dBA – for the perfect night’s sleep.

Dual Barrier Coating

The patented and world’s first Dual Barrier Coating from Mitsubishi Electric prevents dust and dirt from accumulating on the inner surface of the indoor unit; keeping your heat pump clean year-round. Keeping key internal components like the heat exchanger, fan and internal duct clean is important for both home comfort and efficiency. Not only does dust and dirt build-up typically create unpleasant odours, it also forces a heat pump to work harder, which can result in significantly impaired energy efficiency.

Next Generation R32 EcoCore Technology

R32 is a refrigerant with just one-third the global warming potential of R410A and has zero ozone depletion potential. R32 offers increased energy efficiency, and is said to be the next generation of refrigerants

Washable Air Purifying Filter

The EcoCore AP Series is equipped with an Air Purifying Filter. This washable filter traps particles such as dust, pollen and other airborne contaminants, generating stable antibacterial and deodorising effects. The size of the three-dimensional surface has been increased from previous models, enlarging the filter capture area. These features give the Air Purifying Filter better dust collection performance than conventional filters.

Horizontal Airflow

The EcoCore AP Series eliminates uncomfortable draughts with horizontal airflow in cooling mode, by first spreading airflow evenly across the ceiling.

Blue Fin Condenser

The heat exchanger of the outdoor has been treated with Blue Fin anti-corrosion treatment slowing the corrosion process caused by salt and sulphur in the air especially in coastal and high sulphur areas.

Night Mode

For the perfect night’s sleep; dimming the operation indicator light, disabling any beeping from the unit, and lowering the outdoor operating noise level by 3dBA.

Optional Wi-Fi Control Upgrade

With the addition of award-winning Mitsubishi Electric Wi-Fi Control, you can control and monitor your heat pump from absolutely anywhere via your smartphone, tablet or online account.

Read more and try a demonstration

Optional Plasma Quad Connect for Healthier Air

Designed to integrate with your existing AP Series Heat Pump, this high-performance two-stage advanced air filtration module, cleans and minimises dust and other allergens for better indoor air quality, all year round.

Learn more

Specifications

MSZ-AP42VGD2 // Classic AP 42 High Wall Heat Pump System

· Function: Cooling/Heating · Type: Single Split, Inverter
Rated
· Capacity - Cooling: 4.2 kW · Capacity - Heating: 5.4 kW
· Capacity - Cooling (min. - max.): 0.9 - 4.8 kW · Capacity - Heating (min. - max.): 1.3 - 6.0 kW
· Power Input - Cooling: 1.19 kW · Power Input - Heating: 1.43 kW
· Current - Cooling [In+Outdoor] (Rated): 5.30 A · Current - Heating [In+Outdoor] (Rated): 6.30 A
Energy Rating Residential
· ZERL - Cooling (Cold/Mixed/Hot): 4.0 / 4.0 / 4.0 · ZERL - Heating (Cold/Mixed/Hot): 2.0 / 2.5 / 3.5
· TCSPF (Cold/Mixed/Hot): 5.90 / 5.53 / 5.79 · HSPF (Cold/Mixed/Hot): 3.88 / 4.35 / 5.05
· EER / COP: 3.53 / 3.78 · AEER / ACOP: 3.52 / 3.77
Energy Rating Commercial
· TCSPF (Cold/Mixed/Hot): 9.56 / 7.80 / 6.66 · HSPF (Cold/Mixed/Hot): 4.26 / 4.73 / 5.12
Performance
· Operation Range - Cooling: -10 / +46 degC · Operation Range - Heating: -15 / +24 degC

MSZ-AP42VGD2-A1 - Wall Mounted Classic AP42 Indoor Unit - White

· Function: Cooling/Heating · Type: Single Split, Inverter
Nominal Capacity
· Capacity - Cooling: 4.2 kW · Capacity - Heating: 5.4 kW
· Sound Level - Cooling (Low - Super High, dB(A)): 26 / 29 / 35 / 40 / 46 · Sound Level - Heating (Low - Super High, dB(A)): 26 / 29 / 35 / 40 / 46
· Air Volume - Cooling (Super High, Litre/sec): 90-223 · Air Volume - Heating (Super High, Litre/sec): 88-233
· Refrigerant: R32 · Liquid Pipe Size (OD, mm): 6.35
· Gas Pipe Size (OD, mm): 9.52 · Max. Pipe Length (m): 20
· Max. Pipe Height (m): 12 · Power Supply: 230V / Single Phase / 50 Hz
· Dimensions (WxDxH, mm): 798 x 219 x 299 · Weight: 10.5 kg

MUZ-AP42VG2-A1 - R32 Inverter Outdoor Unit

· Function: Cooling/Heating · Type: Single Split, Standard Inverter
· Operation Range - Cooling: -10 / +46 degC · Operation Range - Heating: -15 / +24 degC
· Sound Level - Cooling (dB(A)): 51 · Sound Level - Heating (dB(A)): 52
· Air Volume - Cooling (Litre/sec): 90-233 · Air Volume - Heating (Litre/sec): 88-233
· Power Supply: Single phase, 230 V, 50Hz · Refrigerant: R32
· Liquid Pipe Size (OD, mm): 6.35 · Gas Pipe Size (OD, mm): 9.52
· Max. Pipe Length (m): 20 · Max. Pipe Height (m): 12
· Dimensions (WxDxH, mm): 800 x 285 x 550 · Weight: 35 kg

·  Rating Conditions (AS / NZS 3823):
   Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB.     Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

·  Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

·  Dry function will not work when the room temperature is below 13°C.

·  Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

·  Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

·  Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
   EER = Energy Efficiency Ratio
   COP = Coefficient of Performance
   AEER# = Annual Energy Efficiency Ratio
   ACOP# = Annual Coefficient of Performance
   #These include standby power in the rating calculation

·  Star Ratings based on the Seasonal Energy Rating standard for New Zealand - cold zone [GEMS 2019]

Downloads

Support

AP Classic Series