8.5kW Packaged Hydrobox System

PUHZ-W85VAA-H

With all the heating and cooling ability of the Ecodan Cylinders, the Ecodan Hydrobox is a small form factor heating and cooling powerhouse. The hydrobox can be connected to underfloor, fan coils and/or radiators and provide a whole home central heating solution. For users looking for domestic hot water, the hydrobox can be connected to a heat pump compatible coiled cylinder, while still providing whole home heating. At a similar size to a conventional gas hot water heating system, the small form factor hydrobox is a highly adaptable solution for retrofit or new builds. The system comprises of the 8.5kW PUHZ-W85VAA-BS outdoor packaged unit, the EHPX-VM2C hydrobox and FTC5 controller.

Discontinued Product

Features

Specifications

PUHZ-W85VAA - Ecodan Monobloc Air Source Heat Pump

Function: Hot Water Heating
Type: Monobloc Air Source Heat Pump
Refrigerant Type: R410A
HEATING (A7/W35)*¹
Capacity (kW): 9.00
Power Input (kW): 2.15
COP: 4.18
HEATING (A2/W35)*²
Capacity (kW): 8.50
Power Input (kW): 2.68
COP: 3.17
OPERATING
Operation Ambient Temperature (°C DB)*4: -20 ~ +35°C
Sound Pressure Level at 1m (dBA)*¹: 48
Low Noise Mode (dBA)*¹: 42
WATER DATA
Water Pipe Size: 1" BSP Parallel Thread. ISO 228/1-G1B)
Flow Rate (l/min): 25.8
Water Pressure Drop (kPa): 13.5
ELECTRICAL DATA
Power Supply: 230V / Single Phase / 50 Hz
Maximum Current / Fuse Rating (A): 23 / 25
GENERAL
Dimensions (WxDxH, mm): 950 x 330 + 30*³ x 943
Weight (kg): 79
Notes

*1 Under normal heating conditions at outdoor temp: 7°CDB / 6°CDB, outlet water temp 35°C, inlet water temp 30°C as tested to BS EN14511.
*2 Under normal heating conditions at outdoor temp: 2°CDB / 1°CDB, outlet water temp 35°C, inlet water temp 30°C.
*4 Heating maximum ambient temperature - 21°CDB, DHW hot water maximum ambient temperature - 35°CDB.

EHPX-VM2CR3 - FTC5 Packaged Hydrobox for R410A Units

Type: FTC6 Packaged Hydrobox for R32 Units
Operating Ambient Temperature: 0 ~ +35°C (RH<80%)
Sound Power Level [dBA]: 28
WATER DATA
Water Pipe Connections [mm]: 28mm Compression
Primary Pump: Grundfos UPM2K 15 - 75 130
Primary Expansion Vessel [L]: 10
Charge Pressure [MPa (Bar)]: 0.1 (1)
Target Temperature Range
Space Heating Flow Temperature [°C]: 25 - 60
Space Heating Room Temperature [°C]: 10 - 30
WATER SAFTEY DEVICES - Water Circuit
Control Thermistor [°C]: 1 - 80
Pressure Relief Valve [MPa (Bar)]: 0.3 (3)
Flow Sensor (Minimum Flow 5.0L/min): Supplied
WATER SAFTEY DEVICES - Booster Heater
Manual Reset Thermostat [°C]: 90
Thermal Cut-out (for dry run prevention) [°C]: 121
Pressures
ELECTRICAL DATA - Control Board
Power Supply: 230-240V / Single Phase / 50 Hz
Current [A]: 1.95
Breaker [A]: 10
ELECTRICAL DATA - Booster Heat
Power Supply: 230-240V / Single Phase / 50 Hz
Capacity [kW]: 2
Current [A]: 9
Breaker [A]: 16
GENERAL
Dimensions (WxDxH) [mm]: 530 x 360 x 800
Weight (Empty / Full) [kg]: 37 / 42
Notes

*1 Depending on the ambient conditions, unit may not reach the set temperature.

Support