8.5kW 300L Hydronic Cylinder System

PUZ-WM85VAA-BS 300L

The Ecodan hydronic outdoor unit and indoor cylinder provide whole home heating and domestic hot water with fast heat-up times using plate heat exchanger technology. The system is suitable for underfloor, radiator and fan coil heating systems.

New
$ POA
Select a Size

Features

Specifications

PUZ-WM85VAA-BS - 8.5kW R32 Packaged Outdoor Unit

Function: Hot Water Heating
Type: Packaged Air Source Heat Pump
Refrigerant Type: R32
HEATING (A7/W35)*1
Capacity [kW]: 8.50
Power Input [kW]: 1.77
COP: 4.80
HEATING (A2/W35)*2
Capacity [kW]: 8.50
Power Input [kW]: 2.42
COP: 3.51
COOLING (A35/W7)*3
Capacity [kW]: 7.50
Power Input [kW]: 2.38
EER: 3.15
COOLING (A35/W18)*4
Capacity [kW]: 7.50
Power Input [kW]: 1.53
EER: 4.90
OPERATING RANGE
Heating Operation Ambient Temperature [°C DB]: -20 ~ +24
Cooling Operation Ambient Temperature [°C DB]: +10 ~ +46
DHW Operation Ambient Temperature [°C DB]: -20 ~ +35
OPERATING CHARACTERISTICS
Sound Pressure Level at 1m [dBA]*¹: 45
Flow Rate [L/min]: 10.8 - 24.4
ELECTRICAL DATA
Power Supply: 230V / Single Phase / 50 Hz
Maximum Current / Fuse Rating [A]: 22.0 / 25
GENERAL
Water Pipe Size: 1" BSP Parallel Thread. ISO 228/1-G1B)
Dimensions (WxDxH) [mm]: 1050 x 480 x 1020
Weight [kg]: 98
Notes

*1 Under normal heating conditions at outdoor temp: 7°CDB / 6°CDB, outlet water temp 35°C, inlet water temp 30°C including pump input based on EN14511.
*2 Under normal heating conditions at outdoor temp: 2°CDB / 1°CDB, outlet water temp 35°C, inlet water temp 30°C including pump input based on EN14511.
*3 Under normal cooling conditions at outdoor temp: 35°CDB / 34°CDB, outlet water temp 7°C, inlet water temp 12°C including pump input based on EN14511
*4 Under normal cooling conditions at outdoor temp: 35°CDB / 34°CDB, outlet water temp 18°C, inlet water temp 23°C including pump input based on EN14511
*5 Grille

ERPT30X-VM6EE - FTC7 Hydronic Indoor Cylinder

Type: Ecodan Hydronic Cylinder
Operating Ambient Temperature*1: 0 ~ +35°C (RH<80%)
Sound Power Level [dBA]: 40
WATER DATA
Water Pipe Connections Heating / DHW: G1 Compression / G3/4 thread
Nominal Thermal Store Tank Volume [L]: 300
Primary Expansion Vessel [L]: None
Target Temperature Range
DHW Supply Maximum Temperature [°C]: 40 - 60
Space Heating Flow Temperature [°C]*2: 20 - 60
Space Heating Room Temperature [°C]: 10 - 30
Space Cooling Flow Temperature [°C]: 5 - 25
WATER SAFTEY DEVICES - Primary Circuit
Control Thermistor THW3 [°C]: 1 - 80
Pressure Relief Valve [MPa (Bar)]: 1.0 (10)
Flow Sensor (Minimum Flow 5.0L/min): Supplied
WATER SAFTEY DEVICES - Booster Heater
Manual Reset Thermostat [°C]: 90
DHW Control Thermistor THW1 [°C]: 75
Thermal Cut-out (for dry run prevention) [°C]: 121
ELECTRICAL DATA - Control Board
Power supply: 230-240V / Single Phase / 50 Hz
Current [A]: 1.95
Breaker [A]: 10
ELECTRICAL DATA - Booster Heat
Power supply: 230-240V / Single Phase / 50 Hz
Capacity [kW]: 2+4
Current [A]: 26
Breaker [A]: 32
GENERAL
Dimensions (WxDxH) [mm]: 595 x 680 x 2050
Weight (Empty / Full) [kg]: 105 / 412
Notes

*1. The cylinder environment must frost-free.

·  Nominal operating condition:
   (A7/W35) – Outside air temperature (DB/WB): 7/6°C, Water temperature (inlet/outlet) 30/35°C.
   (A35/W7) – Outside air temperature (DB/WB): 35/24°C, Water temperature (inlet/outlet) 12/7°C.

·  Power Input: At distance of 1m from outdoor unit.

·  Power input figures do NOT include pump input figures as pump input depends on local system configuration.

·  Split type specifications are just examples of the case that the units are connected to a plate heat exchanger produced by Alfa Laval. Actual specifications depend on local system configuration. The specifications above are based on Alfa Laval ACH70-50H Heat Exchanger being used.

Downloads

Support

Warranty

  • Mitsubishi Electric Ecodan Hot Water Heat Pumps come with a 5 Year Parts and Labour Warranty.

    Warranty commences from the date the system is purchased and installed. The installer must also fill out and return a BDT commissioning form applicable to the original purchaser. The installer must also have completed the Ecodan training course. Equipment defects covered by this warranty will be repaired or replaced at the discretion of BDT without cost to the owner for parts or direct repair labour. A BDT authorised repair company shall carry out the repair or replacement during normal business hours.

    Any Mitsubishi Electric Ecodan parts or equipment replaced under the warranty will be warranted in accordance with the provisions of this warranty for the remainder of the original warranty period or 12 months from the completion of the repair, whichever is the greater.

    Except where inconsistent with the owner?s statutory rights and the rights given by this warranty, all other warranties and all liability of BDT for any loss or damage direct and consequential is expressly excluded.

    For full details view warranty terms and conditions.pdf (125 KB)