EcoCore AP 50 High Wall Heat Pump

Medium Room System // MSZ-AP50VGKD

The EcoCore AP50 sets a new standard in super energy efficient heating and cooling. With Dual Barrier Coating that prevents dust and dirt build-up on the inner surface, the EcoCore AP50 stays clean year-round; maximising efficiency and home comfort.

Cooling Capacity5.0 kW
Heating Capacity6.0 kW
Select a Size
Select a Contoller

Features

Whisper Quiet

Starting from barely a whisper, the EcoCore AP Series ensures you only feel the warmth, not hear it! Furthermore, the addition of Night Mode means the outdoor operating noise level drops by a further 3dBA – for the perfect night’s sleep.

Dual Barrier Coating

The patented and world’s first Dual Barrier Coating from Mitsubishi Electric prevents dust and dirt from accumulating on the inner surface of the indoor unit; keeping your heat pump clean year-round. Keeping key internal components like the heat exchanger, fan and internal duct clean is important for both home comfort and efficiency. Not only does dust and dirt build-up typically create unpleasant odours, it also forces a heat pump to work harder, which can result in significantly impaired energy efficiency. Dual Barrier Coating prevents dust and oil build-up on the interior of the heat pump for the ultimate in peace of mind, ease and comfort.

Next Generation R32 EcoCore Technology

R32 is a refrigerant with just one-third the global warming potential of R410A and has zero ozone depletion potential. R32 offers increased energy efficiency, and is said to be the next generation of refrigerants

Built-In Wi-Fi Control

For the ultimate in aesthetics and heat pump control no matter where you are, the Black Diamond LN Series comes equipped with a Wi-Fi Interface inside a hidden pocket in the indoor unit.

Night Mode

For the perfect night’s sleep; dimming the operation indicator light, disabling any beeping from the unit, and lowering the outdoor operating noise level by 3dBA.

Horizontal Airflow

The EcoCore AP Series eliminates uncomfortable draughts with horizontal airflow in cooling mode, by first spreading airflow evenly across the ceiling.

Washable Air Purifying Filter

The EcoCore AP Series is equipped with an Air Purifying Filter. This washable filter traps particles such as dust, pollen and other airborne contaminants, generating stable antibacterial and deodorising effects. The size of the three-dimensional surface has been increased from previous models, enlarging the filter capture area. These features give the Air Purifying Filter better dust collection performance than conventional filters.

Specifications

MSZ-AP50VGKD // EcoCore AP 50 High Wall Heat Pump System

· Function: Cooling/Heating · Type: Single Split, Inverter
Rated
· Capacity - Cooling: 5.0 kW · Capacity - Heating: 6.0 kW
· Capacity - Cooling (min. - max.): 1.4 - 6.2 kW · Capacity - Heating (min. - max.): 1.4 - 8.0 kW
· Power input - Cooling: 1.32 kW · Power input - Heating: 1.62 kW
· Star rating - Cooling: 3.0 · Star rating - Heating: 3.0
· EER / COP: 3.79 / 3.70 · AEER / ACOP: 3.78 / 3.70
· Current - Cooling [In+Outdoor] (Rated): 5.90 A · Current - Heating [In+Outdoor] (Rated): 7.10 A
Performance
· Operation Range - Cooling: -10 / +46 degC · Operation Range - Heating: -15 / +24 degC

MSZ-AP50VGKD-A1 - Wall Mounted Indoor Unit - White

· Function: Cooling/Heating · Type: Single Split, Inverter
Nominal Capacity
· Capacity - Cooling: 5.0 kW · Capacity - Heating: 6.0 kW
· Sound Level - Cooling (Low - Super High, dB(A)): 28 / 33 / 39 / 44 / 49 · Sound Level - Heating (Low - Super High, dB(A)): 29 / 37 / 41 / 45 / 48
· Air volume - Cooling (Super High, Litre/sec): 258 · Air volume - Heating (Super High, Litre/sec): 268
· Refrigerant: R32 · Liquid pipe size (OD, mm): 6.35
· Gas pipe size (OD, mm): 12.7 · Max. pipe length (m): 20
· Max. pipe height (m): 12 · Power supply: 230V / Single Phase / 50 Hz
· Dimensions (WxDxH, mm): 798 x 219 x 299 · Weight: 10.5 kg

MUZ-AP50VG-A1 - R32 Inverter Outdoor Unit

· Function: Cooling/Heating · Type: Single Split, Standard Inverter
· Operation Range - Cooling: -10 / +46 degC · Operation Range - Heating: -15 / +24 degC
· Sound Level - Cooling (dB(A)): 54 · Sound Level - Heating (dB(A)): 56
· Air volume - Cooling (Litre/sec): 675 · Air volume - Heating (Litre/sec): 675
· Power supply: Single phase, 230 V, 50Hz · Refrigerant: R32
· Liquid pipe size (OD, mm): 6.35 · Gas pipe size (OD, mm): 12.7
· Max. pipe length (m): 20 · Max. pipe height (m): 12
· Dimensions (WxDxH, mm): 800 x 285 x 714 · Weight: 40kg

·  Rating Conditions (AS / NZS 3823):
   Cooling – Indoor: 27°C DB, 19°C WB. Outdoor: 35°C DB.     Heating – Indoor: 20°C DB, Outdoor: 7°C DB, 6°C WB.

·  Sensible Cooling Conditions, Indoor: 27°C DB, 20°C WB. Outdoor: 35°C DB.

·  Dry function will not work when the room temperature is below 13°C.

·  Colour: Heat pump units shown may not be colour accurate, please ensure you view an actual unit for colour matching.

·  Maximum length is inclusive of height differential. i.e. (20m length/12m high) means the pipe can be 12m high and 8m across for a total length of 20m.

·  Measure of Energy Efficency: A calculated measurement of energy efficiency for both heating and cooling using the ratio of kW input to kW output.
   EER = Energy Efficiency Ratio
   COP = Coefficient of Performance
   AEER# = Annual Energy Efficiency Ratio
   ACOP# = Annual Coefficient of Performance
   #These include standby power in the rating calculation

Downloads

Support

Optional

Connect multiple indoor units to a single outdoor unit.

This system gives you the freedom to select the indoor model best suited to each and every room in your home. Multi-Split Systems are designed to allow multiple indoor units of varying capacity and type to be connected to just one outdoor unit, enhancing exterior aesthetics by reducing the number of outdoor units required.

MSZ-AP50VGKD Indoor Unit can be connected to the following Multi Room Systems.

Multi-Split system outdoor unit. (WxDxH, mm): 800 x 285 x 550. Cooling/Heating capacity: 5.2/6.1kW. Weight: 37kg. Liquid / Gas Pipe (OD, mm): 6.35 x2 / 9.52 x2. Either a minimum of 1 or maximum combination 2 indoor units (up to Class 50), with max. class total of 75.
Multi-Split system outdoor unit. (WxDxH, mm): 840 x 330 x 710. Cooling/Heating capacity: 5.4/7.0kW. Weight: 58kg. Liquid / Gas Pipe (OD, mm): 6.35 x3 / 9.52 x3. Requires a minimum combination of 2 and a maximum of 3 indoor units (up to Class 50), with max. class total of 100.
Multi-Split system outdoor unit. (WxDxH, mm): 840 x 330 x 710. Cooling/Heating capacity: 7.1/8.0kW. Weight: 59kg. Liquid / Gas Pipe (OD, mm): 6.35 x4 / 9.52 x3 + 12.7 x1. Requires a minimum combination of 2 and a maximum of 4 indoor units (up to Class 60), with max. class total of 125.
Multi-Split system outdoor unit. (WxDxH, mm): 950x 330 x 796. Cooling/Heating capacity: 8.0/8.8kW. Weight: 63kg. Liquid / Gas Pipe (OD, mm): 6.35 x4 / 9.52 x3 + 12.7 x1. Requires a minimum combination of 2 and a maximum of 4 indoor units (up to Class 71), with max. class total of 145.
Multi-Split system outdoor unit. (WxDxH, mm): 9500 x 330 x 796. Cooling/Heating capacity: 10.0/10.0kW. Weight: 64kg. Liquid / Gas Pipe (OD, mm): 6.35 x5 / 9.52 x4 + 12.7 x1. Requires a minimum combination of 2 and a maximum of 5 indoor units (up to Class 71), with max. class total of 171.
Multi-Split system outdoor unit. (WxDxH, mm): 950 x 330 x 1048. Cooling/Heating capacity: 12.0/13.2kW. Weight: 88kg. Liquid / Gas Pipe (OD, mm): 6.35 x6 / 9.52 x5 + 12.7 x1. Requires a minimum combination of 2 and a maximum of 6 indoor units (up to Class 80), with max. class total of 180.
Multi-Split system outdoor unit. (WxDxH, mm): 1050 x 330(25) x 981. Cooling/Heating capacity: 12.5/14.0kW. Weight: 93kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 162. Central Branch Box(s): When installing two Branch Boxes, use Brazing or Flare Tee for dual Branch Box Connection.
Multi-Split system outdoor unit. (WxDxH, mm): 1050 x 330(25) x 981. Cooling/Heating capacity: 14.0/16.0kW. Weight: 93kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 182. Central Branch Box(s): When installing two Branch Boxes, use Brazing or Flare Tee for dual Branch Box Connection.
Multi-Split system outdoor unit. (WxDxH, mm): 1050 x 330 x 981. Cooling/Heating capacity: 15.5/16.5kW. Weight: 93kg. Liquid / Gas Pipe (OD, mm): 9.52 / 15.88. Requires a minimum combination of 2 and a maximum of 8 indoor units (upto Class 100), with max. class total of 202. Central Branch Box(s): When installing two Branch Boxes, use Brazing or Flare Tee for dual Branch Box Connection.
EcoCore AP Series