
The Power of 2
Mitsubishi Electric Ducted Heat Pump with Lossnay Heat Recovery Ventilation Combined
Breathe easier and enjoy year-round comfort with The Power of 2. This advanced home climate solution combines a Mitsubishi Electric ducted whole-home Air Conditioning system with Lossnay Fresh Air Heat Recovery Ventilation.
Whether you’re building a new home or upgrading an existing one, this integrated solution delivers discreet whole-home heating or cooling*, improved indoor air quality, and exceptional energy efficiency all year-round.
* Does not heat and cool simultaneously.
Power of 2 Starts with the Right Ducted System
The Power of 2 is designed to blend seamlessly into your home. Hidden within the ceiling cavity, the system delivers unobtrusive heating or cooling*, as well as fresh air ventilation through minimalist ceiling grilles or vents, preserving your home’s aesthetics while maintaining year-round comfort.
The system offers flexible ducting options and adaptable airflow configurations to accommodate a wide range of floor plans and architectural designs. Mitsubishi Electric’s advanced splittable ducted system also makes installation easier in existing homes where roof space or ceiling access may be restricted, providing greater versatility without compromising performance.
Paired with Lossnay Heat Recovery Ventilation, the right ducted system becomes The Power of 2 — whole-home comfort and continuous fresh filtered air in one integrated solution.
* Does not heat and cool simultaneously.
A Lossnay Heat Recovery Ventilation System
The Lossnay Balanced Pressure Ventilation System recovers heat from the stale, damp air it extracts from your home and then uses that energy to pre-warm or pre-cool the incoming filtered fresh air. This means that when Lossnay is combined with your ducted system, your home can be brought to the desired temperature faster because the heating system is not required to work as hard to do so.
By keeping a home well-ventilated, the air is also much drier, further speeding up the efficient heating process. In addition, because fresh air is brought in from the outside and not from the attic, air quality is maximised. When these two systems are combined and work together, they will ultimately create a drier, healthier environment for your family.
Combat Condensation & Prevent Overheating
Modern airtight homes can trap moisture-laden air in winter, leading to mould, and overheat in summer, creating uncomfortable living spaces. Lossnay Mechanical Ventilation tackles both issues, ensuring fresh, filtered air, year-round comfort, and improved energy efficiency.
Learn more
Fresh Filtered Air Not Attic Air
Lossnay removes the stale air from the inside and introduces a constant flow of fresh filtered air from the outside, so you and your family can breathe easy all year round.
Learn more
Super Energy Efficient Help Save on Power Bills
Unlike traditional positive pressure ventilation systems, Lossnay is a balanced pressure solution that pre-warms (or cools) incoming air which can help save on your power bill. It does this by recovering heat energy from the outgoing stale damp air. The end result is a healthier, drier and warmer home.
Learn more
Retains Heat to Pre-Warm Incoming Air
Lossnay’s unique Heat Recovery Technology collects up to 86%* of the heat energy in outgoing air which is then used to pre-warm or cool the fresh air vented in. Moisture build up is minimised while healthy humidity levels are maintained in the most energy efficient way possible.
Learn moreInstallation Example of Ducted Heat Pump Combined with Lossnay Ventilation
Optional Wi-Fi Interlock* for Total Home Control
Seamlessly combine your Mitsubishi Electric Ducted Heat Pump and Lossnay Energy Recovery Ventilation System through your Wi-Fi Control App for ultimate visibility and control.
Because your Ducted Heat Pump needs to be in fan, heating or cooling mode for the connected Lossnay system to operate, you can now choose from two innovative modes to customise your climate control setup.
Use the Power Interlock mode to enjoy set-and-forget convenience. In this mode both systems will always automatically activate together no matter which system you initially turn on.
Opt for Fresh Air Fan Interlock mode to prioritise fresh air circulation regardless of whether the ducted system is turned on. In this mode the Lossnay System will override a ducted system that is turned off and automatically activates the system’s Fan Mode. As a result, fresh air continues to circulate efficiently throughout the home.
*To enable Wi-Fi Interlock Control, both units will require a Wi-Fi Interface.
The complete solution
What Your Power of 2 Delivers
A fully integrated whole-home comfort solution combining:
Key Features of a Power of 2 Solution
The Range
Build Your Power of 2 System
Download the Brochures
Product Resources
Get started
Ready to experience The Power of 2?
Talk to a specialist about a fully integrated ducted heat pump and Lossnay Ventilation solution for your home.
Or call us on 0800 784 382





